Find information on thousands of medical conditions and prescription drugs.

Oxytetracycline

Oxytetracycline is known as a broad-spectrum antibiotic due to its activity against such a wide range of infections. It was the second of the Tetracyclines to be discovered. more...

Home
Diseases
Medicines
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
Methoxsalen
OCL
Octabenzone
Octanoic acid
Octopamine
Octreotide
Ofloxacin
Ofloxacin
Olanzapine
Omeprazole
Oncovin
Ondansetron
Opium
Oratane
Oretic
Orinase
Orlistat
Ornidazole
Ornithine
Orotic acid
Orphenadrine
Ortho Evra
Oruvail
Ovcon
Ovral
Ovrette
Oxaliplatin
Oxamniquine
Oxandrin
Oxandrolone
Oxaprozin
Oxazepam
Oxcarbazepine
Oxetine
Oxibendazole
Oxiracetam
Oxprenolol
Oxybenzone
Oxybuprocaine
Oxycodone
Oxycodone
Oxymetazoline
Oxymetholone
Oxymorphone
Oxytetracycline
Oxytocin
P
Q
R
S
T
U
V
W
X
Y
Z

History

It was first found near Pfizer laboratories in a soil sample yielding the soil bacillus, Streptomyces rimosus. In 1953, a celebrated American biochemist, Robert B Woodward, son of a Scottish immigrant woman, worked out the chemical structure of Oxytetracycline, enabling Pfizer to mass produce the drug under the tradename, Terramycin. This discovery by Woodward was a major advancement in Tetracycline research and eventually lead to the synthesis of an Oxytetracycline derivative, Doxycycline, probably the most commonly used Tetracycline nowadays.

Indications

Oxytetracycline, like other Tetracyclines, is used to treat many infections common and rare (see Tetracycline antibiotics group). Its better absorption profile makes it preferable to tetracycline for moderately severe acne at a dosage of 250-500mg four times a day for usually 6-8 weeks at a time, but alternatives sould be sought if no improvement occurs by 3 months.

It is often used to treat Spirochaetal infection and Clostridium wound infection in patients sensitive to Penicillin.

The standard dose is 250-500mg six hourly by mouth. In particularly severe infections this dose may be increased accordingly. Occasionally, Oxytetracycline is given by intramuscular injection or topically in the form of cream or eyedrops.

Vetenary indications

Oxytetracycline is used to control the outbreak of American Foulbrood and European Foulbrood in honeybees.

Formulation

Tablets containing 250mg Tablets of Oxytetracycline as the dihydrate.

Read more at Wikipedia.org


[List your site here Free!]


Histomorphometric and mechanical analysis of the hydroxyapatite-bone interface after electromagnetic stimulation
From Journal of Bone and Joint Surgery, 1/1/06 by Fini, M

AN EXPERIMENTAL STUDY IN RABBITS

We investigated the effect of stimulation with a pulsed electromagnetic field on the osseointegration of hydroxyapatite in cortical bone in rabbits. Implants were inserted into femoral cortical bone and were stimulated for six hours per day for three weeks.

Electromagnetic stimulation improved osseointegration of hydroxyapatite compared with animals which did not receive this treatment in terms of direct contact with the bone, the maturity of the bone and mechanical fixation. The highest values of maximum push-out force (F^sub max^) and ultimate shear strength (σ^sub u^) were observed in the treated group and differed significantly from those of the control group at three weeks (F^sub max^; p

Various attempts have been made to modify the surfaces of joint prostheses in order to provide early fixation and to reduce loosening.1 However, aseptic loosening is often related to subjective factors such as endogenous bone healing, rather than to the surface characteristics of biomaterials.1

Stimulation by pulsed electromagnetic field has been reported to improve cell-biomaterial interactions, antibiotic efficacy in implant infections3 and symptoms in patients with a loose hip prosthesis.4 Recently, it has been shown that it also has significant biological effects in other tissues such as the heart and the skin5 and alters the A2A adenosine receptor density and function in human neutrophils, thereby reducing inflammation.6 Implants with increased surface porosity and roughness show more bone contact than those with a smooth surface. They are increasingly used in dental and orthopaedic surgery but they may promote inflammation. There have, however, been only a few reports in the last 20 years on the effect of pulsed electromagnetic stimulation on the biomaterial-bone interface (Table I).1,8-13

In a previous study in vivo we showed the positive effect of pulsed electromagnetic stimulation on the osseointegration of hydroxyapatite (HA) cylinders implanted in trabecular bone in rabbits. Histomorphometric and microstructural data showed both an acceleration of osseointegration and an improvement in the quality of the bone at the interface.9 A limitation of that study was the lack of mechanical testing. We have now investigated the histomorphometry, microhardness and mechanics of HA cylinders implanted in trabecular bone in rabbits.

Materials and Methods

The study was performed in compliance with European and Italian law on animal experimentation. It was approved by the Ethical Committee of the University of Bologna and the Ministry of Health. The animals were operated on under general anaesthesia. Antibiotics and analgesics were given in the immediate post-operative period as previously described.

We used 12 adult male New Zealand rabbits of mean weight 3.250 kg (SD 0.35). The mid-diaphysis of the femur was exposed and two holes 2.9 mm in diameter were drilled bilaterally across the lateral cortices. An HA cylinder, 3 mm in diameter and 5 mm in length, was pressed into each hole. The skin was sutured in two layers. As a kinetic marker of bone mineralisation, oxytetracycline was injected intramuscularly at a dose of 30 to 35 mg/kg at days 10, 9, 2 and 1 before the animals were killed.

On the first post-operative day the animals were randomly divided into two groups: six were exposed to a pulsed electromagnetic field for six hours a day for three consecutive weeks and six were not and were the control group. Animals were killed three and six weeks after implantation. A total of 12 implants was studied at each experimental time. Six specimens were used for mechanical testing and six for histology, histomorphometry and studies on microhardness. All the measurements for all the techniques were carried out by blinded operators.

Pulse electromagnetic field generator. Electromagnetic stimulators were provided by IGEA (Biostim; IGEA SrI, Carpi, Italy). They created an electromagnetic field with a frequency of 75 Hz, an intensity of 1.6 mT and a duty cycle of 1.35 ms.

Two coils were placed outside the cage so that they were positioned directly over the area to be stimulated, and were connected to a generator. The stimulators were turned on for six hours a day for three consecutive weeks. Each rabbit was held in a fixed position during stimulation inside the cage but was allowed free activity in the cage for 18 hours a day when not being treated. The same conditions were applied to the six control animals except that the coils were not energised.

Hydroxyapatite. HA powder was manufactured according to the mechanochemical method previously described.9 A series of cylinders was produced with these powders by slip casting in a mould. The shaped samples obtained were treated for an hour at 1250°C and sterilised at 120°C for 20 minutes before implantation.

Histomorphometry. The retrieved femora were stripped of soft tissues, fixed in 4% buffered paraformaldehyde and dehydrated in graded series of alcohols for undecalcified bone and embedded in polymethylmethacrylate. The blocks were sectioned along a plane parallel to the major axis of the cylinder using a Leica 1600 diamond saw microtome (Leica SpA, Milan, Italy). To allow comparison between the areas under investigation, a series of 40 µm thick sections and spaced 200 µm apart were obtained. Unstained sections were viewed under fluorescent light to evaluate the deposition of new bone around the implants. The sections were stained with 2% basic fuchsin, Methylene Blue and fast green. Routine histology and histomorphometric analyses were made using transmission and polarised light microscopy (Axioskop Carl Zeiss GmbH, Jena, Germany) and image-analysis software (KS 300; Kontron Electronic GmbH, Eiching bei Munchen, Germany).

We calculated the affinity index, which is the length of the region where bone is in direct contact with the implant divided by the total length of the interface multiplied by 100. Dynamic histomorphometry by tetracycline labelling of the newly-formed bone at the HA-bone interface gave measurement of the rate of mineral apposition (µm/day) and the rate of bone formation µm^sup 2^/µm/day).

These are reported as indices of osteoblast teams and their activity following the nomenclature and methodology approved by the American Society of Bone and Mineral Research.14

Microhardness. The same blocks containing the residual part of the implanted HA were used to measure the hardness of bone by means of an indentation test (Microhardness VHMT 30; Leica, Wien, Austria). The detailed method has been described previously.9 Briefly, measurements of microhardness were made tangential to the interface with a Vickers indenter applied to the bone at a load of 0.05 Kgf and at a dwell time of 5 s. The Vickers hardness degree (HV) was calculated by dividing the indentation force by the surface of the imprint (four pyramid surfaces) observed under the microscope. The mean value for each sample was calculated as a mean of ten for each area at two sites: a) in the regrown bone, within 200 µm from the interface (HV^sub 200^) and b) in the pre-existing host bone, at 1000 µm from the HA-bone interface (HV^sub 1000^). Finally, the bone maturation index (BMI) was calculated as a percentage of the ratio HV^sub 200^/HV^sub 1000^.

Mechanical push-out test. Periosteal overgrowth was removed from the specimens by grinding to obtain proper alignment. They were kept wet with normal saline at 4°C until the mechanical tests were carried out at no more than 36 hours after retrieval. The specimens were then warmed in 0.9% NaCI at room temperature for at least three hours and finally conditioned in 0.9% NaCI at 37°C during the subsequent stages of the mechanical testing which was performed within an hour.

The push-out test was carried out by placing the femoral segments on a support jig using an MTS apparatus (Sintech-1/M; MTS Adamel Lhomargy, Ivry sur Seine, France). The force was applied to the implant from the medullary side at a constant cross-head speed of 1 mm per minute. We measured the maximum push-out force (F^sub max^) and the ultimate shear strength at the interface (ou) defined as σ^sub u^ = F^sub max^/(π OD t), where OD is the outer diameter of the cylinder (mm) and t is the thickness of the cortical bone (mm).

After the push-out tests, random samples collected from each group were fixed in 2% glutaraldehyde/0.1 M phosphate buffer, dehydrated in ethanol, dried at CO2 (top critical point 30) mounted on aluminium stubs using a carbon tape and coated with a 20 nm Au/Pd layer (Coating Unit Polaron; Polaron Equipment Ltd, Watford, UK). The specimens were then examined by SEM (J840A; Jeol Tokyo, Japan) in secondary-electrons mode to determine the failure mode.15

Statistical analysis. This was performed using SPSS 10.1 software (SPSS/PC Inc., Chicago, Illinois). Data were reported as the median (SEM) at a level of significance of p

Results

Histological findings. There was ingrowth of bone tissue in both the pulsed electromagnetic field and control groups without fibrous interposition. Bone apposition was higher in the pulsed electromagnetic field group at three weeks when small areas of bone not in contact with the HA surface were still visible. At three weeks trabecular endosteal and periosteal hypertrophy was seen in the pulsed electromagnetic field group compared with the control animals. New lamellar bone tissue formed at the HA-bone interface of the pulsed electromagnetic field animals and was intimately bound to HA (Fig. 1a). New woven bone was still growing and filling the gap between the host bone and HA in the control group at three weeks (Fig. 1b).

At six weeks, newly-formed lamellar bone containing mature Haversian systems was seen in the pulsed electromagnetic field group. In the control group, the interface was filled with young bone tissue (Fig. 2a). Bone remodelling was more advanced in the pulsed electromagnetic field than in the control animals (Fig. 2b).

Osseointegration of HA samples was significantly increased in the pulsed electromagnetic field group compared with the control group in terms of the affinity index, mineral apposition rate and bone formation rate (p

Microhardness. The microhardness of the regrown bone (HV^sub 200^) was increased by electromagnetic treatment at three weeks (Table III) but as expected, treatment did not have any effect on that of pre-existing host bone.

Mechanical push-out tests. There was an improvement in the osseointegration of HA implants in the pulsed electromagnetic field treated group, in terms of the maximum push-out force (F^sub max^) and ultimate shear strength (σ^sub u^) (Table III). The highest values of F^sub max^ and σ^sub u^ were observed in the pulsed electromagnetic field treated group at three weeks and differed significantly from those of the control group at the same experimental time (p

Finally, significant (p

Discussion

Enhancement of bone ingrowth is needed to improve the rate of success in terms of the reliability and longevity of orthopaedic implants. Adjuvant therapies could improve osseointegration, particularly when endogenous osteogenetic potential is expected to be low.16 Our in vivo study aimed at evaluating the effect of electromagnetic stimulation on the fixation of HA implants in the cortical bone of rabbits during the initial phases of bone healing.

We found a positive effect of electromagnetic stimulation on bone apposition, mineralisation and mechanical attachment to HA. The dynamic histomorphometric parameters showed a positive effect of treatment on the formation and mineralisation of bone at three weeks. The data strongly confirm those obtained by Canè, Botti and Soana17 when studying the healing process of transcortical holes in diaphyseal compact bone. They observed a significant increase in mineral apposition rate in electromagnetically treated cases in comparison with the control group and concluded that treatment stimulated the activity of osteoblasts.17 At six weeks HA osseointegration was not increased compared with that at three weeks and this steady state was accompanied by a decrease in mineral apposition rate and BFR.

At the HA-bone interface the greatest mineralisation and microhardness were observed after three weeks of electromagnetic stimulation. Finally, the mechanical results paralleled those obtained from measurement of microhardness. Electromagnetic stimulation produced a strong implant-bone fixation at three weeks, which was reduced at six weeks but gave mechanical values higher than those of the control group at the same time. Because of the lack of data on the osteogenic effect of electromagnetism after the stimulation is turned off, and on implants in cortical bone, we suggest that there is a different temporal pattern of bone ingrowth and remodelling between treated and untreated animals. Bone remodelling started earlier in the treated animals when bone apposition to HA was almost complete and could have been responsible for the observed results. Push-out data were, at least in part, influenced by the characteristics of bone around the implants. The remodelling phase of bone is already at an advanced stage in electromagnetically-treated animals, while in untreated animals at six weeks bone density is increased, as reported by other authors.18 When studying biomaterials with different rates of osseointegration, they observed a lower percentage of bone apposition combined with a higher bone density. In untreated animals, the lower rate of osseointegration of HA observed at both three and six weeks may have resulted in an increased bone mass around the implants.18

Good correlation has been reported between the microhardness and the mechanical parameters and could explain the linear relationship between findings of the biomechanical push-out tests and the data on microhardness.9,19 No correlation between mechanical (microhardness and pushout) and the affinity index was observed. It may be explained by the unequal distribution of stresses along the interface during the push-out tests as well as by the variations in the biomechanical characteristics of the bone tissue in contact with the implant.15,20

The physical parameters of the electromagnetic field were the same as those of our previous study because of the positive results obtained for HA osseointegration and in previous in vitro and in vivo studies on bone healing.2,9,17,21-23 Other studies supported the choice of a treatment period of three weeks because of evidence of the major differences between the treated and untreated animals at this time.1,9,13

In summary, electromagnetic stimulation appears to be a promising treatment for accelerating HA osseointegration in both trabecular and cortical bone. However, the weakness of our transcortical non-weight-bearing model is that it does not reflect the microenvironment around hip prostheses and it uses small animals.24 Issues such as biomechanical loading, physical forces, micromovement at the interface, fluid pressure waves, the related host response or changes which occur at the implant-bone interface may be further investigated in joint replacement models in larger animals.

No benefits in any form have been received or will be received from a commerial party related directly or indirectly to the subject of this article.

References

1. Spadaro JA, Albanese SA, Chase SE. Electromagnetic effects on bone formation at implants in the medullary canal in rabbits. J Orthop Res 1990;8:685-93.

2. Torricelli P, Fini M, Giavaresi G, et al. Biomimetic polymethylmethacrylate-based bone substitute: a comparative in vitro evaluation of the effects of pulsed electromagnetic field exposure. J Biomed Mater Res A 12003:64:182-8.

3. Pickering SA, Bayston R, Scammel BE. Augmentation of antibiotic efficacy in infection of orthopaedic implants. J Bone Joint Surg/er/2003;85-B:588-93.

4. Fini M, Giavaresi G, Setti S, et al. Current trends in the enhancement of biomaterial osteointegration: biophysical stimulation, lnt J Artif Organs2004:27:681 -90.

5. Smith TL, Wong-Gibbons D, Maultsby J. Microcirculatory effects of pulsed electromagnetic fields. J Orthop Res 2004:22:80-4.

6. Varani K, Gessi S, Merighi S, et al. Effect of low frequency electromagnetic fields on A2A adenosin receptors in human neutrophils. Br JPnarm3co/2002;136:57-66.

7. Thomsen P, Ericson LE. Inflammatory cell response to bone implant surfaces. In: Davies JE, ed. The bone-biomaterial interlace. Toronto: University of Toronto Press, 1991:153-60.

8. Buzzà EP, Ghibli JA, Arbeiro RH, Barbosa JR. Effects of electromagnetic field on bone healing around commercially pure titanium surface: histologie and mechanical study in rabbits. Implant Dent 2003:12:182-7.

9. Fini M, Cadossi R, Cane V, et al. The effect of pulsed electromagnetic fields on the osteointegration of hydroxyapatite implants in cancellous bone: a morphologic and microstructural in vivo study. J Orthop Res 2002:20:756-63.

10. Ijiri K, Matsunaga S, Fukuyama K, et al. The effect of pulsing electrical fields on bone ingrowth into a porous coated implant. Anticancer Res 1996,16:2853-6.

11. Matsumoto H, Ochi M, Abiko Y, et al. Pulsed electromagnetic fields promote bone formation around dental implants inserted into the femurs of rabbits. Clin Oral Implants Res 2000:11:354-60.

12. Ottani V, Raspanti M, Martini D, et al. Electromagnetic stimulation on the bone growth using backscattered electron imaging. Micron2002:33:121 -5.

13. Shimizu T, Zerwekh JE, Violeman T, et al. Bone ingrowth into porous calcium phosphate ceramics: influence of pulsing electromagnetic fields. J Orthop Res 1988:6: 248-58.

14. Parfitt AM, Drezner MK, Gliorieux FH, et al. Bone histomorphometry: standardization of nomenclature, symbols and units. J Bone Miner Res 1987:2:595-610.

15. Dhert WJA, Jansen JA. The validity of a single push-out test. In: An YH, Draughin RA, eds. Mechanical testing of bone and the bone-implant interface. Boca Raton: CRC Press LLC, 2000:477-88.

16. LeGeros RZ, Craig RG. Strategies to affect bone remodelling: osteointegration. J Bone Miner Res 1993:8(Suppl 2):583-96.

17. Canè V, Botti P, Soana S. Pulsed magnetic fields improve osteoblast activity during the repair of an experimental osseous defect. J Orthop Res 1993:11:664-70.

18. Hulshotf JEG, Hayakawa T, van Dijk K, et al. Mechanical and histologie evaluation of Ca-P plasma-spray and magnetron sputter-coated implants in trabecular bone of the goat. J Biomed Mater Res 1997:36:75-83.

19. Huja SS, Katona TR, Roberts WE. Microhardness testing of bone. In: An YH, Draughin RA, eds. Mechanical testing of bone and the bone-implant interface. Boca Raton: CRC Press LLC, 2000:247-56.

20. Corten FG, Caulier H, van der Waerden JP, et al. Assessment of bone surrounding implants in goats: ex vivo measurements by dual x-ray absorptiometry. Biomaterials 1997;18:495-501.

21. Torricelli P, Fini M, Giavaresi G, Cane V, Giardino R. In vitro evaluation of the effects of electromagnetic fields used for bone healing. Electro Magnetobioll 998:17: 335-42.

22. Canè V, Botti P, Farneti D, Soana S. Electromagnetic stimulation of bone repair: a histomorphometric study. J Orthop Res 1991:9:908-17.

23. Capanna R, Donati D, Masetti C, et al. Effect of electromagnetic fields on patients undergoing massive bone graft following bone tumor resection: a double blind study. Clin Orthop 1994;306:213-21.

24. Konttinen YT, Zhao D, Beklen A, et al. The microenvironment around total hip replacement prostheses. Clin Orthop 2005;430:28-38.

M. Fini, G. Giavaresi, R. Giardino, F. Cavani, R. Cadossi

From The Rizzoli Orthopaedic Institute, Bologna, Italy

* M. Fini, MD, Researcher

* G. Giavaresi, MD, Researcher

* R. Giardino, MD, Professor Experimental Surgery Laboratory

Research Institute Codivilla-Putti, Rizzoli Orthopaedic Institute, Via di Barbiano 1/10, 40136 Bologna, Italy.

* F. Cavani, BSc, Researcher Department of Anatomy and Histology

University of Modena and Reggio Emilia, 41100 Modena, Italy.

* R. Cadossi, MD, Director Laboratory of Clinical Biophysics, ICEmB IGEA SrI, Via Parmenide 10/a, 41012 Carpi, Modena, Italy.

Correspondence should be sent to Dr M. Fini; e-mail: milena.fini@ior.it

©2006 British Editorial Society of Bone and Joint Surgery

doi:10.1302/0301-620X.88B1. 16496 $2.00

J Bone Joint Surg [Br] 2006;88-B: 123-8.

Received W March 2005; Accepted after revision 24 June 2005

Copyright British Editorial Society of Bone & Joint Surgery Jan 2006
Provided by ProQuest Information and Learning Company. All rights Reserved

Return to Oxytetracycline
Home Contact Resources Exchange Links ebay