A box of Pulmozyme
Find information on thousands of medical conditions and prescription drugs.

Dornase alfa

Dornase alfa (Pulmozyme®) is a highly purified solution of recombinant human deoxyribonuclease I (rhDNase), an enzyme which selectively cleaves DNA. Pulmozyme hydrolyzes the DNA in sputum/mucus of CF patients and reduces viscoelasticity in the lungs, promoting improved clearance of secretions.

Home
Diseases
Medicines
A
B
C
D
Dacarbazine
Dactinomycin
Dalmane
Danazol
Dantrolene
Dapoxetine
Dapsone
Daptomycin
Daraprim
Darvocet
Darvon
Daunorubicin
Daunorubicin
Daypro
DDAVP
Deca-Durabolin
Deferoxamine
Delsym
Demeclocycline
Demeclocycline
Demerol
Demulen
Denatonium
Depakene
Depakote
Depo-Provera
Desferal
Desflurane
Desipramine
Desmopressin
Desogen
Desogestrel
Desonide
Desoxyn
Desyrel
Detrol
Dexacort
Dexamethasone
Dexamfetamine
Dexedrine
Dexpanthenol
Dextran
Dextromethorphan
Dextromoramide
Dextropropoxyphene
Dextrorphan
Diabeta
Diacerein
Diacetolol
Dial
Diamox
Diazepam
Diazoxide
Dibenzepin
Diclofenac
Diclohexal
Didanosine
Dieldrin
Diethylcarbamazine
Diethylstilbestrol
Diethyltoluamide
Differin
Diflucan
Diflunisal
Digitoxin
Digoxin
Dihydrocodeine
Dihydroergotamine
Dihydrotachysterol
Dilantin
Dilaudid
Diltahexal
Diltiazem
Dimenhydrinate
Dimercaprol
Dimetapp
Dimethyl sulfoxide
Dimethyltryptamine
Dimetridazole
Diminazene
Diovan
Dioxybenzone
Diphenhydramine
Diphenoxylate
Dipipanone
Dipivefrine
Diprivan
Diprolene
Diproteverine
Dipyridamole
Disulfiram
Disulfiram
Dizocilpine
Dobutamine
Docetaxel
Docusate sodium
Dofetilide
Dolasetron
Dolobid
Dolophine
Domperidone
Donepezil
Dopamine
Dopram
Doral
Doramectin
Doriden
Dornase alfa
Doryx
Dostinex
Doxapram
Doxazosin
Doxepin
Doxil
Doxil
Doxorubicin
Doxy
Doxycycline
Doxyhexal
Doxylamine
Drisdol
Drixoral
Dronabinol
Droperidol
Drospirenone
Duloxetine
Durabolin
Duragesic
Duraphyl
Duraquin
Dutasteride
Dv
Dyclonine
E
F
G
H
I
J
K
L
M
N
O
P
Q
R
S
T
U
V
W
X
Y
Z

Read more at Wikipedia.org


[List your site here Free!]


Device selection and outcomes of aerosol therapy: evidence-based guidelines
From CHEST, 1/1/05 by Myrna B. Dolovich

Background: The proliferation of inhaler devices has resulted in a confusing number of choices for clinicians who are selecting a delivery device for aerosol therapy. There are advantages and disadvantages associated with each device category. Evidence-based guidelines for the selection of the appropriate aerosol delivery device in specific clinical settings are needed.

Aim: (1) To compare the efficacy and adverse effects of treatment using nebulizers vs pressurized metered-dose inhalers (MDIs) with or without a spacer/holding chamber vs dry powder inhalers (DPIs) as delivery systems for [beta]-agonists, anticholinergic agents, and corticosteroids for several commonly encountered clinical settings and patient populations, and (2) to provide recommendations to clinicians to aid them in selecting a particular aerosol delivery device for their patients.

Methods: A systematic review of pertinent randomized, controlled clinical trials (RCTs) was undertaken using MEDLINE, EmBase, and the Cochrane Library databases. A broad search strategy was chosen, combining terms related to aerosol devices or drugs with the diseases of interest in various patient groups and clinical settings. Only RCTs in which the same drug was administered with different devices were included. RCTs (394 trials) assessing inhaled corticosteroid, [beta]-agonist, and anticholinergic agents delivered by an MDI, an MDI with a spacer/ holding chamber, a nebulizer, or a DPI were identified for the years 1982 to 2001. A total of 254 outcomes were tabulated. Of the 131 studies that met the eligibility criteria, only 59 (primarily those that tested [[beta].sub.2]-agonists) proved to have useable data.

Results: None of the pooled metaanalyses showed a significant difference between devices in any efficacy outcome in any patient group for each of the clinical settings that was investigated. The adverse effects that were reported were minimal and were related to the increased drug dose that was delivered. Each of the delivery devices provided similar outcomes in patients using the correct technique for inhalation.

Conclusions: Devices used for the delivery of bronchodilators and steroids can be equally efficacious. When selecting an aerosol delivery device for patients with asthma and COPD, the following should be considered: device/drug availability; clinical setting; patient age and the ability to use the selected device correctly; device use with multiple medications; cost and reimbursement; drug administration time; convenience in both outpatient and inpatient settings; and physician and patient preference.

Key words: aerosols; bronchodilators; corticosteroids; drug delivery systems; dry powder inhalers; metaanalysis; metered-dose inhalers; nebulizers

Abbreviations: CFC = chlorofluorocarbon; DPI = dry powder inhaler; ED = emergency department; MDI = metered-dose inhaler; NPPV = noninvasive positive pressure ventilation; PEFR = peak expiratory flow rate; RCT = randomized controlled trial; sGaw = specific airway conductance

**********

The use of inhaled aerosol medications for the treatment of pulmonary diseases, which became well-established in the last half of the 20th century, has advantages over oral and parenteral routes of delivery. The use of inhaled aerosols allows selective treatment of the lungs directly by achieving high drug concentrations in the airway while reducing systemic adverse effects by minimizing systemic drug levels. (1) Inhaled [[beta].sub.2]-agonist bronchodilators produce a more rapid onset of action than oral delivery. Some drugs are only active with aerosol delivery (eg, for asthma patients, cromolyn and ciclesonide; for cystic fibrosis patients, dornase alfa). Aerosol drug delivery is painless and often convenient. For these reasons, the National Asthma Education and Prevention Program guidelines (2) favor aerosol inhalation over the oral route or parenteral (ie, subcutaneous, IM, or IV) route. Similarly, the National Heart, Lung, and Blood Institute/World Health Organization Global Initiative for Chronic Obstructive Lung Disease recommended that bronchodilator medications are central to symptom management in COPD patients and that inhaled therapy is preferred. (3)

There are also disadvantages to aerosol drug therapy. One of the most important disadvantages is that specific inhalation techniques are necessary for the proper use of each of the available types of inhaler device. A less than optimal technique can result in decreased drug delivery and potentially reduced efficacy. (4,5) Improper inhaler technique is common among patients. (6-8) The proliferation of inhalation devices that are available for patients has resulted in a confusing number of choices for the health-care provider and in confusion for both clinicians and patients trying to use these devices correctly. Several studies have demonstrated lack of physician, nurse, and respiratory therapist knowledge of device use. (9-13) Inhaler devices are less convenient than oral drug administration insofar as the time required for drug administration may be longer and some patients may find the device less portable. This is particularly true for conventional compressed-air nebulizers, the oldest of the currently used types of aerosol delivery devices.

Device manufacturers have long been aware of the importance of portability and ease of use with aerosol delivery devices. As a result, these devices have evolved over time. From the 19th century until 1956, compressed-air nebulizers (also called jet nebulizers) were the only devices that were in common clinical use for the administration of inhaled aerosol drugs. In 1955, the pressurized metered-dose inhaler (MDI) was developed at Biker Laboratories (now 3M Pharmaceuticals; St. Paul, MN). (14) Ultrasonic nebulizers, which utilize high-frequency acoustical energy for the aerosolization of a liquid, were introduced in the 1960s. (15,16) In 1971, Bell and colleagues (17) introduced the first dry powder inhaler (DPI), known as the Spinhaler, for the inhalation of eromolyn sodium. This and subsequent DPIs have been "breath-actuated," providing drug only when demanded by patient inhalation, thus avoiding a common error with MDI use, the improper timing of inhaler actuation. Breath-actuated MDI devices (eg, the Autohaler; 3M Pharmaceuticals) are also triggered by patient inhalation to release the drug on demand.

Investigators developed open-tube spacer devices, intended for use with MDIs, in the late 1970s. (18-20) The addition of a one-way valve (holding chamber) (18) or blind reservoir (ie, reverse-flow spacer) (21,22) al lowed the aerosol delivered by the MDI to be contained in the spacer for a finite period of time, thereby circumventing the need for the coordinated actuation of the MDI with inhalation. Other spacer/ holding chamber designs followed, and today there are several devices that vary in design, shape, size, and assembly. The design of MDIs changed little between 1956 and the 1980s. However, the 1987 Montreal protocol mandated the phaseout of the use of chlorofluorocarbons (CFCs) as propellants in all MDIs. This resulted in a redesign of MDIs in the 1990s, utilizing hydrofluoroalkane propellants. (22) Some of these formulations produce aerosols with different characteristics that behave differently in patients than their predecessors. (23)

Each type of aerosol device has its own advantages and disadvantages (Table 1). Nebulizer/compressor systems require minimal patient cooperation and coordination, but are cumbersome and time-consuming to use. Matching nebulizers with associated air compressors is necessary to assure optimal efficiency of drug delivery. MDIs are quicker to use and highly portable, but require the most patient training to ensure coordination for proper use. Up to 70% of patients fail to use them properly. The improper timing of MDI actuation with breath initiation is a common problem. (7) DPIs are easier to use than MDIs because they are breath-actuated, but require a relatively rapid rate of inhalation in order to provide the energy necessary for drug aerosolization. Younger patients and patients in acute distress may not be able to generate the necessary flow rates. (2,24) Breath-actuated MDIs are also easier to use, but are currently available in the United States for only a single drug (ie, the [[beta].sub.2]-agonist pirbuterol). Holding chambers used with MDIs remove the necessity of careful timing between inhalation and MDI actuation. However, they are more bulky to carry than the MDI by itself or a DPI. The improper use of holding chambers (eg, placing multiple puffs in the chamber before inhalation or waiting too long between MDI actuation and inhalation) can actually reduce drug delivery to the lungs.

Several factors can guide clinicians on the choice of a device for a specific patient. One factor is the age of the subject (Table 2). (2) Another factor is the availability of the drug formulation, as not all drugs are available in each type of aerosol delivery device. The clinical setting (eg, outpatient, emergency department (ED), hospitalized inpatient, or intensive care setting) and the disease being treated (eg, COPD vs asthma) also influence the choice of aerosol device.

Several systematic reviews and metaanalyses related to the selection of an aerosol delivery device have been published. In a metaanalysis, Turner et al (25) concluded that bronchodilator delivery by means of nebulizer or MDI is equivalent in the treatment of adults with acute airflow obstruction. A systematic review by Amirav and Newhouse (26) compared MDIs with accessory devices to nebulizers in children with acute asthma. While their results showed no differences between the types of delivery systems, it was concluded that the MDI with an accessory device (ie, a spacer or holding chamber) should be considered the preferred mode of aerosol delivery. A systematic review (27) of the management of acute exacerbations of COPD concluded that there is insufficient evidence that either an MDI or a nebulizer is superior. Cates et al (28) and Cares, (29) in systematic reviews of spacers and holding chambers vs nebulizers for [[beta].sub.2]-agonist treatment of acute asthma, concluded that an MDI with a holding chamber produces outcomes that are at least equivalent to those achieved with the use of a nebulizer. Several systematic reviews (30-32) have compared MDIs to DPIs and have concluded that there is no evidence that either device is superior to the other for bronchodilator therapy.

While systematic reviews provide key evidence summaries, they do not present specific recommendations for practice. The reasons for this include a focus on restricted populations and outcomes, and the lack of a process to ensure recommendations reflect patients' values and preferences. (33) However, clinicians require information and guidance concerning the best estimates of benefits and risks of alternatives, and concerning the explicit tradeoffs between these benefits and risks, or, in other words, evidence-based guidelines. Therefore, despite the availability of the above systematic reviews, we believe that evidence-based guidelines are still needed. Consequently, the intent of this project was to assess the available scientific evidence addressing the question of whether device selection affects efficacy and the adverse effects of treatment. Therefore, we set out to systematically review relevant evidence from randomized, placebo-controlled clinical trials and to provide general recommendations based on the tradeoffs that this evidence provides. Our recommendations relate to issues that clinicians should consider in selecting a particular therapeutic aerosol delivery device for their patients in each of several commonly encountered clinical settings.

METHODOLOGY

We undertook a systematic overview of the pertinent literature. The databases that were searched were MEDLINE, Embase, and the Cochrane Library (Table 3, available on-line only). A broad search strategy was chosen to combine terms relating to aerosol devices or drugs with those relating to the diseases of interest in various patient groups and in a number of clinical settings (Fig 1). Only randomized controlled trials (RCTs) in human subjects published in English were selected. The search identified an initial set of approximately 2,100 publications spanning the years 1972 to 2000. Two reviewers independently assessed each abstract of these publications to determine whether they met the eligibility criteria (ie, RCT addressing the relevant population, intervention, and outcome). This review identified 394 RCTs assessing inhaled corticosteroid, [[beta].sub.2]-agonist, and anticholinergic agents that were delivered by MDI, MDI with spacer/holding chamber, nebulizer, or DPI. These 394 studies were coded (for setting, population, disease, and device) to provide a second screening to identify studies in which the same drug was administered with different devices. Studies were excluded if they only compared devices of the same type (eg, DPI with DPI) or only compared oral or parenteral therapy with the aerosol therapy. Data were then extracted from the remaining 131 studies. A total of 254 outcomes were tabulated (Table 4, available on-line only). Because this proved unwieldy, we created a taxonomy of 10 categories (Table 5) and, as many of the outcomes were similar expressions of the same measurement, specified a hierarchy of outcomes within this taxonomy. Of the 131 studies, only 59 proved to have useable data (Table 6). These studies primarily tested [[beta].sub.2]-agonists. Few studies of corticosteroids met our eligibility criteria.

[FIGURE 1 OMITTED]

Separate metaanalyses were carried out for each specific clinical setting being considered. The weighted standardized difference between treatment groups in the outcome of interest was calculated using the mean scores and their SDs. We combined results across end points of FE[V.sub.1], peak flow, and specific airway conductance (sGaw), and calculated the effect size in SD units. For studies that made measurements at multiple time points, the last time point was used for analysis. For studies with multiple doses, analyses using the first dose and the last dose were performed. All outcomes reported are in SD units. In studies that provided data for more than one of these outcomes, we used the outcome that was highest in the hierarchy. To assess whether the magnitude of the heterogeneity of differences in the apparent treatment effect across studies was greater than one might expect by chance, we conducted a test based on the [chi square] distribution with N-1 degree of freedom, where N is the number of studies. No important effects were seen in any of the group analyses, and there was very little heterogeneity in any of the data. In general, our statistical methods relied on the approaches described by Fleiss (34) and by Hedges and Olkin. (35)

We found that the studies were heterogeneous in purpose, design, and patient selection, and determined that these descriptors would influence the interpretation and relevance of the studies for clinical use by patients. Therefore, we grouped the studies that were reviewed into three general types (types 1, 2a, and 2b) based on the intended purpose and specific study design used.

Type 1 Trials: Device Performance Under Conditions of Actual Clinical Use

These trials were intended to compare the effectiveness of the devices and drug being studied in a setting of "real-world" clinical use with the measured outcomes relevant to the accepted indication for the drug in this setting. Studies that compared the effect of a [[beta].sub.2]-agonist agent delivered by nebulizer, DPI, and/or MDI in patients presenting to the ED with acute asthma are an example of this type of study. These studies typically evaluate outcomes such as improvement in lung function and oxygenation or hospital admission rate. Studies that compare the effect of inhaled corticosteroids delivered by different devices over a period of weeks, and assess daily asthma symptoms, [[beta].sub.2]-agonist use, and daily peak flow measurement are other examples of such studies.

Type 2 Trials: Device Performance in the Clinical Laboratory Setting

These studies compare drug delivery to the lungs and the clinical response to drugs administered by different devices under carefully controlled clinical laboratory conditions. These studies were typically performed to satisfy regulatory requirements during the process of drug development and registration. Participating patients are usually carefully trained in and monitored for the proper use of the devices. These studies do not directly evaluate the performance of the devices in settings and conditions in which patients actually use them as part of the management of their asthma or COPD (eg, a patient who awakens in the night with acute bronchospasm). The most common examples of this type of study are outpatient evaluations of devices containing short-acting [[beta].sub.2]-agonists. Most of these studies measure increases in lung function in response to the [[beta].sub.2]agonist in patients who have developed a mild-to-moderate degree of bronchospasm after having their usual asthma medication withheld. A few measure the inhibition of bronchial provocation with exercise compounds (eg, methacholine or histamine). Type 2 studies can be divided into two subtypes based on the kind of analysis performed in the study.

Type 2a Trials: Analyzing Differences in Response Variables: These studies typically compare mean increases in lung function values (eg, FE[V.sub.1]) produced by the different devices. These studies are termed response axis comparisons by the US Food and Drug Administration and are now widely recognized to be relatively insensitive to true differences in drug delivery by different devices. (36] Typically, the doses used are near the top of the [[beta].sub.2]-agonist dose-response curve that patients exhibit in this setting. As a result, the studies are commonly unable to distinguish differences in response to either a different dose via the same device or to delivery by different devices.

Type 2b Trials: Estimating Differences in Clinical Potency: These studies establish dose-response curves for each of the devices being compared and then use differences in the position of these curves to estimate differences in the clinical potency of the devices (known as the relative potency or potency ratio). The results of this analysis yield statements such as "1 actuation (or microgram of drug) delivered from 'device A' is equivalent to 'X' number of actuations (or micrograms) delivered from "device B 7' The analysis also calculates a confidence interval for the estimate of the relative potency as an indicator of how reliable the estimate is. These studies are termed "dose-scale comparisons" (36) and are recognized as being the most reliable way of identifying true difference in drug delivery to the site of action in the lung.

Members of the Writing Committee assumed responsibility for drafting individual sections of the final document, including the recommendations. To grade the strength of the recommendations, we used a system adopted by the Health and Science Policy Committee of the American College of Chest Physicians (Table 7). The draft document was reviewed by all members of the Writing Committee for content and accuracy.

RESULTS AND RECOMMENDATIONS

Device Selection in the Hospital Acute Care Setting

Aerosol Delivery of Short-Acting [[beta].sub.2]-Agonists in the Hospital ED: Nineteen RCTs that compared aerosol delivery devices in the ED met the criteria for inclusion in the analysis. All used a parallel design and assessed the response to one of three [[beta].sub.2]-agonist bronchodilators (ie, albuterol, metaproterenol, or terbutaline). No studies were available that compared nebulizers to MDIs alone in patients with acute asthma presenting to the ED. The majority of these studies compared delivery by nebulizer to that by an MDI with a spacer/holding chamber. All were type i studies that enrolled patients presenting to the ED with acute asthma symptoms. Only 3 of the 19 studies included in the analysis studied delivery by DPI in the ED setting. None of the studies specifically stated that they had screened patients for their ability to use the device correctly. The studies also omitted a detailed discussion of the device technique that was used to inhale the medications. Most of these studies measured acute physiologic responses to treatment, and a smaller number measured effects on asthma sign/symptom scores. Few studies offer other clinically important outcome measures such as hospital admission rate, time in the ED, and readmissions to the ED. The cost of care and the fraction of patients who cannot use the device correctly were not reported in any of the studies. Eight studies (37-44) randomized pediatric patients to receive a [[beta].sub.2]-agonist agent by nebulizer or MDI with spacer/ holding chamber (ie, Aerocell Lactantes [Grunewald-Danes; Chile], AeroChamber [Trudell Medical; London, ON, Canada], and Volumatic [Glaxo Wellcome; London, UK]) [Table 8]. Collectively, these studies enrolled patients with ages ranging from < 1 to 17 years. Most investigators reported no significant difference between these two techniques for pulmonary function measures (ie, peak flow and FE[V.sub.1]) or symptom scores. Metaanalyses of symptom scores and pulmonary function results showed no differences between the nebulizer and the MDI with a spacer/ holding chamber (Fig 2, 3). One study (40) reported greater patient preference for file MDI with a spacer/ holding chamber, and another study (38) reported shorter treatment times with the use of an MDI and a spacer/ holding chamber. None of the studies included in the analysis evaluated DPI use in pediatric patients presenting to the ED.

In adult patients reporting to the ED with asthma symptoms (Table 9), six studies (45-50) compared [[beta].sub.2] agonist delivery by nebulizer to that by an MDI with a spacer/holding chamber. No study reported a significant difference in pulmonary function response to the two methods of delivery (Fig 3). Two studies (47,48) addressed other important outcomes and reported no significant differences between devices for time in the ED, hospital admission rate, and frequency of ED discharge at 6 h. Similar findings were reported in studies (51-53) including both pediatric (ie, adolescent) and adult patients in ED settings. The three studies (47,54,55) evaluating the use of a DPI (eg, Rotahaler [GlaxoSmithKline; Ware, UK] and Turbuhaler [AstraZeneca; Lund, Sweden]) with adult patients in this setting reported no significant differences between DPI and the other two delivery methods for pulmonary function response and for other outcomes such as hours to hospital discharge (Table 10). Similar findings were noted for pediatric patients presenting to the ED in a study that was not included in this analysis. (56)

[FIGURES 2-3 OMITTED]

One study (57) evaluated aerosol delivery devices in an ambulance setting. No significant differences were reported in pulmonary function response to a nebulizer, an MDI used alone, or an MDI with a spacer/holding chamber, but the effects on respiratory rate and duration of treatment were significantly better for the use of the MDI with holding chamber than for the other two methods.

Adverse effects appeared to be more common with nebulizer use. Heart rate change tended to be greater in patients using a nebulizer, but file effect across studies was significant only when pediatric and adult studies were analyzed together (Fig 4). These differences in heart rate between devices tended to be small in magnitude. One study (38) found vomiting to be more common with nebulizer use than with use of an MDI with a spacer/holding chamber, which likely was due to the larger dose given by nebulizer in these subjects.

[FIGURE 4 OMITTED]

Summary of RCT Results

* The delivery of [[beta].sub.2]-agonists in the ED setting by nebulizers or MDIs with holding chambers (eg, AeroChamber, Volumatic, or InspirEase [Key Pharmaceuticals; Kenilworth, NJ]) is equally effective for improving pulmonary fimction and reducing symptoms of acute asthma in both adult and pediatric patients (quality of evidence: good).

* The delivery of [[beta].sub.2]-agonists in the ED setting by DPI (eg, Rotahaler or Turbuhaler) has been inadequately studied, but trials in adults have suggested DPIs may be as effective as nebulizers or MDIs with spacer/ holding chambers (quality of evidence: low).

* Nebulizer use in the ED setting is associated with greater increases in heart rate than with the use of an MDI with spacer/holding chamber, suggesting that a larger systemically absorbed dose is administered by nebulizers (quality of evidence: good).

Recommendations

1. Both the nebulizer and MDI with spacer/ holding chamber are appropriate for the delivery of short-acting [[beta].sub.2]-agonists in the ED. Quality of evidence: good; net benefit: substantial; strength of recommendation: A.

2. Because data for DPIs are limited, and high quality data for standard MDIs (without spacer/ holding chamber) and breath-actuated MDIs are unavailable, we are unable to recommend the use of these devices in the ED until more information is available. Quality of evidence: low; net benefit: none; strength of recommendation: I.

3. Many factors would lead the clinician to appropriately select a particular type of aerosol delivery device in this setting. These factors include the patient's ability to use the device correctly, the preferences of the patient for the device, the unavailability of an appropriate drug/device combination, the compatibility between the drug and delivery device, the lack of time or skills to properly instruct the patient in the use of the device or to monitor the appropriate use, and the cost of therapy. Quality of evidence: low; net benefit: substantial; strength of recommendation: B.

Aerosol Delivery of Short-Acting [[beta].sub.2]-Agonists in the Inpatient Hospital Setting

Considering the common use of aerosolized drugs in hospitalized patients, there are surprisingly few studies that have compared aerosol delivery devices in this setting (Table 11). (53,58-63) Six type 1 studies (53,58-61,63) included in the analysis compared nebulizers with MDIs having spacer/holding chambers in adult and pediatric patients. These studies reported no significant differences in pulmonary function between nebulizers and MDIs with spacer/holding chambers (Fig 5). One study (62) compared MDI used alone with DPI use and also found no significant difference in peak expiratory flow rate (PEFR). However, as the deposition efficiency of the DPI tested was approximately half that of the MDI tested, the authors elected to compare DPI doses that were twice that for the MDI, with the intent of producing equal responses. Other outcome variables such as length of hospital stay were similar for the nebulizer and MDI with a spacer/holding chamber. Reports of the cost of care are conflicting, without clear evidence of one device resulting in a greater cost than another. There is a paucity of data regarding the ability of patients to use these devices correctly in this setting. For [[beta].sub.2]-agonists, the impact of the differences in the time required to administer the therapy on patient responses was not analyzed.

[FIGURE 5 OMITTED]

The inpatient setting presents a unique opportunity for health-care providers to instruct the patient on the proper use of each device, but the benefit of such an approach has not been assessed in randomized trials.

Summary of RCT Results

* In the inpatient setting, the available evidence suggests that there is no difference in the pulmonary function response between using a nebulizer and using an MDI with a spacer/holding chamber for administering short-acting [[beta].sub.2]-agonist therapy (quality of evidence: good).

Recommendations

1. Both nebulizers and MDIs with spacer/holding chambers are appropriate for use in the inpatient setting. Quality of evidence: good; net benefit: substantial; strength of recommendation: A.

2. Because the data for DPIs, standard MDIs without spacer/holding chambers, and breath-actuated MDIs have been inadequately studied in this setting, we are unable to recommend the use of these devices in patients requiring hospitalization for asthma or COPD until more information is available. Quality of evidence: low; net benefit: none; strength of recommendation: I.

3. Many factors would lead the clinician to appropriately select a particular type of aerosol delivery device in this setting. These include the patient's inability to use the device correctly, the preferences of the patient for the device, the unavailability of the drug/device combination, the compatibility between the drug and the delivery device, the lack of time or skills to properly instruct the patient in the use of the device or in monitoring the appropriate use, and the cost of therapy. Quality of evidence: low; net benefit: substantial; strength of recommendation: B.

Intermittent vs Continuous Nebulizer Delivery of [[beta].sub.2]-Agonists

Continuous aerosol bronchodilator therapy is used occasionally in patients with severe bronchospasm in the ED or ICU. Its use is limited to the most severe exacerbations of asthma. One systematic review (64) supports the equivalence of continuous and intermittent albuterol nebulization in the treatment of acute adult asthma. Continuous vs intermittent administration of [[beta].sub.2]-agonists was compared in six randomized type 1 studies enrolling either adult patients or pediatric patients in the ED and ICUs (Table 12). (65-70) These six studies reported no differences in pulmonary function changes comparing these administration approaches (Fig 6). Changes in asthma score and dyspnea are also similar for both modalities. (65,70) Two studies have reported greater staff (eg, respiratory therapy) time requirements for intermittent nebulization compared to continuous nebulization. (65,70) One study (69) reported a lower hospital admission rate with the use of continuous nebulization in an ED setting, but another study (65) reported no difference in admission rates. Decreased hospital length of stay was associated with the use of continuous nebulization in one study enrolling pediatric patients. (70) Two studies (67,69) reported similar heart rate responses with continuous and intermittent nebulization.

[FIGURE 6 OMITTED]

Summary of RCT Results

* Pulmonary function and asthma symptom scores show similar benefits for continuous and intermittent nebulization of short-acting [[beta].sub.2]-agonists (quality of evidence: good).

* The time requirements for staff administration and maintenance of the therapy are less for continuous nebulization than for intermittent nebulization (quality of evidence: good).

* Adverse effects of [[beta].sub.2]-agonists are similar for continuous and intermittent nebulization of [[beta].sub.2]-agonists (quality of evidence: good).

* The effects of continuous vs intermittent nebulization of [[beta].sub.2]-agonists on hospital admission rate from the ED, hospital length of stay, and cost of care have not been adequately studied (quality of evidence: low).

Recommendation

1. Frequent intermittent nebulization and continuous nebulization are both appropriate alternatives in severely dyspneic patients in the ED or ICU. Quality of evidence: good; net benefit: substantial; strength of recommendation: A. Aerosolized [[beta].sub.2]-Agonists in Patients Receiving Mechanical Ventilation

Patients in the ICU, particularly those receiving mechanical ventilation, present unique challenges for aerosol delivery. Both MDIs and nebulizers can be adapted for use in ventilator circuits, the former requiring a spacer or connector with an integral actuator. Because of compatibility issues, it is currently not possible to use DPIs and breath-actuated MDIs to deliver inhalant medications via a ventilator circuit. Only three RCTs (Table 13) comparing these devices in mechanically ventilated patients were available for analysis. All were type I studies. These compared the effects of short-acting [[beta].sub.2] -agonists on pulmonary mechanics in infants with bronchiolitis, and in adults with asthma and COPD. (71-73) None of these trials compared other outcomes such as the duration of mechanical ventilation, the length of stay in the ICU, the length of hospital stay, the cost of treatment, clinician preference, the relief of dyspnea, or the occurrence of pulmonary complications.

Albuterol was the drug employed in each of the three RCTs included in the analysis. The outcomes evaluated included changes in respiratory system compliance, airway resistance, and expiratory flows. In two of the studies, (71,72) there were no differences in the response to albuterol between MDIs and nebulizers. In the other study, (73) the administration of up to 10 mg albuterol by MDI had no effect, whereas, the administration of 2.5 to 7.5 mg albuterol with a nebulizer produced significant reductions in airway resistance. In this study, however, the adapter employed to connect the MDI to the ventilator circuit had a very low drug delivery efficiency. (73) This underscores the need to give careful attention to the specific details of the system used to deliver aerosolized drugs to intubated, mechanically ventilated patients. (74)

Observational trials (75) have reported that the administration of albuterol with an MDI and chamber spacer produced responses that were comparable to those obtained with albuterol administered by nebulizer. In one randomized crossover study (published following the literature search for these evidence-based guidelines), Duarte et al (76) reported that the airway response to albuterol via MDI with spacer and nebulizer were similar in duration and magnitude for mechanically ventilated patients with COPD. Although it is commonly accepted that an endotracheal tube may affect aerosol deposition patterns by providing a finer aerosol at the tube exit, the presence of airway disease may overwhelm this advantage. (77) There are no deposition/dose-response comparative studies in patients receiving mechanical ventilation, and, thus, no clear recommendations for the dosing of [beta]-agonists in this setting can be made.

The adverse effects of [beta]-agonist administration during mechanical ventilation were determined in two studies. In one, (72) no adverse effects were found after the administration of 270 lag albuterol from an MDI or 2.5 mg administered with a nebulizer. In the study by Manthous et al, (73) premature beats and sinus tachycardia or tremors were noted after the administration of 7.5 mg albuterol with a nebulizer. All of the patients who received a cumulative dose of 15 mg albuterol with a nebulizer developed tachycardia and premature heart beats. No changes in BP or other side effects have been described from albuterol administration in this group of patients.

Although evaluated only in non-RCT studies, several factors are known to have clinically important effects on aerosol delivery during mechanical ventilation. These include the position at which the nebulizer is placed in the circuit, (78,79) the nebulizer brand and its fill volume, (80) the humidification of the inspired gas, (80) the treatment time, (81) the inspiratory time (duty cycle), (79,80) intermittent vs continuous nebulization, (79) the ventilator brand, (81) and the density of the carrier gas. (82) It has been reported that the response to albuterol administered by MDI to mechanically ventilated patients with COPD was not affected by inspiratory flow pattern, pressure controlled ventilation vs volume-controlled ventilation, (83) the level of inspiratory flow, (84) the delivered tidal volume, (85) or the addition of an end-inspiratory pause. (86) When an MDI is used during mechanical ventilation, the use of a spacer device has been shown to increase deposition compared to other in-line actuators. (87)

Noninvasive positive-pressure ventilation (NPPV) is increasingly used in the care of patients with acute exacerbations of COPD. No RCT has compared the delivery of aerosol medications by nebulizer or MDI in this setting. There have, however, been reports of the use of nebulizers (88) or MDIs (89) in conjunction with the use of NPPV.

Summary of RCT Results

* In children and adults receiving mechanical ventilation, the outcomes of [[beta].sub.2]-agonist administration using an MDI with or without a spacer/holding chamber are no different than those observed following [[beta].sub.2]-agonist administration with a nebulizer (quality of evidence: fair).

* High doses of [[beta].sub.2]-agonists administered with a nebulizer are associated with a higher incidence of tachycardia and premature heart beats in mechanically ventilated patients, but there is no difference in adverse effects observed after the administration of albuterol with an MDI compared to those observed after the administration of the drug with a nebulizer (quality of evidence: fair).

* There is insufficient evidence to guide the choice of MDI or nebulizer for patients receiving NPPV (quality of evidence: low).

Recommendations

1. Both nebulizers and MDIs can be used to deliver [[beta].sub.2]-agonists to mechanically ventilated patients. Quality of evidence: fair; net benefit: substantial; strength of recommendation: A.

2. Careful attention to details of the technique employed for administering drugs by MDI or nebulizer to mechanically ventilated patients is critical, since multiple technical factors may have clinically important effects on the efficiency of aerosol delivery. Quality of evidence: low; net benefit: substantial; strength of recommendation: B.

DEVICE SELECTION IN THE OUTPATIENT SETTING

Short-Acting [[beta].sub.2]-Agonists for Asthma in the Outpatient Setting

Twenty-eight RCTs compared devices for the delivery of [[beta].sub.2]-agonists to outpatients. Most trials used a crossover design, and all were of type 2a or 2b. In other words, study outcomes assessed the comparability of the effect in the clinical laboratory setting in patients who had been carefully trained in and screened for proper use of the device. Consequently, they did not directly assess effectiveness as "quick relief' treatment for outpatient asthma symptoms (the primary role that these agents play in the treatment of asthma). (2-3) Some were single-dose studies in which each treatment was administered only once, with measurements being made before and after this treatment. In other studies, treatments were administered on a scheduled daily basis over varying periods of time from as short as 1 day up to a few months. With both of these approaches, however, the primary outcome assessed changes in lung function in the clinical laboratory. Daily asthma symptom scores and adverse effects, mainly changes in heart rate, were assessed in only a few trials.

Twenty-three studies (90-99,101-103,106-115) (both type 2a and 2b) compared the responses to short-acting [[beta].sub.2]-agonists using a DPI vs those using an MDI (without a spacer/holding chamber) in adults with asthma (Tables 14, 15). Outcomes included some type of pulmonary function measurement in all but one trial. In that one study, cough score was the only useable outcome. Metaanalyses comparing FE[V.sub.1], PEFR, and sGaw responses from these studies showed no significant differences between devices, either by separate analysis or when pooled (Fig 7). Six of the trials comparing MDI with DPI were analyzed separately because they employed similar ("comparable") doses of the same drug in the two devices (Table 15). (95,102,103,108,110,114] This allowed for a more direct assessment of device efficiency and effectiveness than in the studies that used different doses and/or drugs in the devices being compared. An analysis of these comparable close studies also found no differences in FE[V.sub.1] PEFR, FVC, or symptoms (see Fig 8 on-line). For trials in which multiple sequential doses were administered by each device, the metaanalysis was performed for both the lowest dose and for the highest dose administered (in 16 trials). Again, no differences were found for FE[V.sub.1], PEFR, sGaw, or FVC. Two studies compared cough or other symptoms, (90,101] and three studies compared changes in heart rate changes. (92,98,115] No differences were found between the MDI and the DPI in pooled analyses of these studies. However, one study (116) reported greater improvements in FE[V.sub.1] for DPI use compared with MDI use, and another study (90) reported greater improvement in cough score for DPI use compared with MDI use.

[FIGURES 7-8 OMITTED]

Four studies compared the MDIs and DPIs in pediatric patients. Two studies (117,118) investigated terbutaline delivered by MDI and by DPI (Turbuhaler). Another study (119) evaluated fenoterol delivery by MDI and DPI. The fourth study (120) enrolled both pediatric and adult patients. None of these studies, either individually or when combined, showed a difference between use of the MDI and use of the DPI.

Fewer data are available comparing the effects of [[beta].sub.2]-agonists inhaled via an MDI without a spacer device vs those inhaled via an MDI with a spacer device in adults or children with asthma in the outpatient setting, (100-121) and only one study (121) met criteria for inclusion in the analysis. This study showed no difference between the two routes for the outcomes FE[V.sub.1], PEFR, or FVC (Table 16).

Eight type 2b studies that compared short-acting [beta]-agonist delivery by different devices were evaluated separately (Table 17). Three studies that compared the dose delivered by nebulizer and MDI with holding chamber each concluded that more than two MDI actuations are required to equal one nebulizer treatment. Pedersen and Bundgaard (122) and Madsen et al (123) estimated that approximately four terbutaline MDI actuations are required to equal a single nebulized treatment with 2.5 to 4.0 mg of terbutaline. Blake et al (124) estimated that approximately 10 MDI actuations of albuterol are required to equal one nebulizer treatment with 2.5 mg albuterol. It is for this reason the more than two MDI actuations are typically used in ED studies comparing MDIs with spacers/holding chambers and nebulizers (Table 8). Type 2B studies by Wong et al, (125) Lofdahl et al, (126) and Bondesson et al (127) compared albuterol delivery via DPI (Turbuhaler) and CFC MDI (Ventolin). All three studies estimated that the dose delivered by the DPI was greater (1.38-fold, 1.98-fold, and 2.0-fold greater, respectively). Confidence intervals for these three estimates overlapped in the region, indicating a twofold to threefold greater potency for the Turbuhaler. In contrast, two type 2B studies (112,128) comparing a Spiros DPI (Elan Pharmaceuticals; Dublin, Ireland) with a CFC MDI (Ventolin) estimated that these devices were approximately equipotent. This draws attention to the fact that differences in the relative amount of drug delivered to the lung depends not only on the general type of device used (DPI vs MDI) but 'also on the specific brand of device being compared (eg, Spiros DPI or Turbuhaler DPI).

Summary of RCT Results

* In the adult and pediatric outpatient population with asthma, available evidence comparing short-acting [[beta].sub.2]-agonist delivery by MDI and DPI show no differences in pulmonary function responses, symptom scores, or heart rate. This remains true when analysis is restricted to type 2b studies that estimate the doses required to produce equal levels of response (called dose-axis comparisons) [quality of evidence: good].

* In a limited number of type 2 studies comparing short-acting [[beta].sub.2]-agonists administered with an MDI to that with an MDI using a spacer or holding chamber, pulmonary function responses were found to be comparable (quality of evidence: low).

* The use of nebulizers for the delivery of short-acting [[beta].sub.2]-agonists in the outpatient setting has not been adequately studied in RCTs (quality of evidence: low).

Recommendations

1. For treatment of asthma in the outpatient setting, both the MDI, used with or without spacer/holding chamber, and the DPI are appropriate for the delivery of short-acting [[beta].sub.2]-agonists. Quality of evidence: good; net benefit: substantial; strength of recommendation: A.

2. The appropriate selection of a particular type of aerosol delivery device in this setting includes the patient's ability to use the device correctly, the preferences of the patient for the device, the availability of the drug/device combination, the compatibility between the drug and delively device, the lack of time or skills to properly instruct the patient in the use of the device or to monitor the appropriate use, the cost of the therapy, and the potential for reimbursement. Quality of evidence: low; net benefit: substantial; strength of recommendation: B.

Inhaled Corticosteroids for Asthma

Four trials (90,104,105,106,129) comparing the use of a DPI with that of an MDI plus spacer for the inhalation of inhaled corticosteroids in adult (90,104,105,129) asthmatic patients in the outpatient setting met the criteria for study inclusion (Table 18). No studies enrolling children were eligible for inclusion. To be able to accurately compare device performance and efficacy, we required that the same drug be delivered via MDI/ spacer and DPI, and this greatly limited the number of useable trials. In these four trials, the same dose of the same corticosteroid was used for the two delivery routes. The durations of these type 1 trials were treatments were administered on a scheduled daily basis over varying periods of time from as short as 1 day up to a few months. With both of these approaches, however, the primary outcome assessed changes in lung function in the clinical laboratory. Daily asthma symptom scores and adverse effects, mainly changes in heart rate, were assessed in only a few trials.

Twenty-three studies (90-99,101-103,106-115) (both type 2a and 2b) compared the responses to short-acting [[beta].sub.2]-agonists using a DPI vs those using an MDI (without a spacer/holding chamber) in adults with asthma (Tables 14, 15). Outcomes included some type of pulmonary function measurement in all but one trial. In that one study, cough score was the only useable outcome. Metaanalyses comparing FE[V.sub.1], PEFR, and sGaw responses from these studies showed no significant differences between devices, either by separate analysis or when pooled (Fig 7).

Six of the trials comparing MDI with DPI were analyzed separately because they employed similar ("comparable") doses of the same drug in the two devices (Table 15). (95,102,103,108,110,114) This allowed for a more direct assessment of device efficiency and effectiveness than in the studies that used different doses and/or drugs in the devices being compared. An analysis of these comparable close studies also found no differences in FE[V.sub.1], PEFR, FVC, or symptoms (see Fig 8 on-line). For trials in which multiple sequential doses were administered by each device, the metaanalysis was per formed for both the lowest dose and for the highest dose administered (in 16 trials). Again, no differences were found for FE[V.sub.1], PEFR, sGaw, or FVC. Two studies compared cough or other symptoms, [90,101) and three studies compared changes in heart rate changes. (92,98,115) No differences were found between the MDI and the DPI in pooled analyses of these studies. However, one study (116) reported greater improvements in FE[V.sub.1] for DPI use compared with MDI use, and another study (90) reported greater improvement in cough score for DPI use compared with MDI use.

Four studies compared the MDIs and DPIs in pediatric patients. Two studies (117,118) investigated terbutaline delivered by MDI and by DPI (Turbuhaler). Another study (119) evaluated fenoterol delivery by MDI and DPI. The fourth study (120) enrolled both pediatric and adult patients. None of these studies, either individually or when combined, showed a difference between use of the MDI and use of the DPI.

Fewer data are available comparing the effects of [[beta].sub.2]-agonists inhaled via an MDI without a spacer device vs those inhaled via an MDI with a spacer device in adults or children with asthma in the outpatient setting, (100,121) and only one study (121) met criteria for inclusion in the analysis. This study showed no difference between the two routes for the outcomes FE[V.sub.1], PEFR, or FVC (Table 16).

Eight type 2b studies that compared short-acting [[beta].sub.2]-agonist delivery by different devices were evaluated separately (Table 17). Three studies that compared the dose delivered by nebulizer and MDI with holding chamber each concluded that more than two MDI actuations are required to equal one nebulizer treatment. Pedersen and Bundgaard (122) and Madsen et al (123) estimated that approximately four terbutaline MDI actuations are required to equal a single nebulized treatment with 2.5 to 4.0 mg of terbutaline. Blake et Al (124) estimated that approximately 10 MDI actuations of albuterol are required to equal one nebulizer treatment with 2.5 mg albuterol. It is for this reason the more than two MDI actuations are typically used in ED studies comparing MDIs with spacers/holding chambers and nebulizers (Table 8). Type 2B studies by Wong et al, (125) Lofdahl et al, (126) and Bondesson et al (127) compared albuterol delivery via DPI (Turbuhaler) and CFC MDI (Ventolin). All three studies estimated that the dose delivered by the DPI was greater (1.38-fold, 1.98-fold, and 2.0-fold greater, respectively). Confidence intervals for these three estimates overlapped in the region, indicating a twofold to threefold greater potency for the Turbuhaler. In contrast, two type 2B studies (112,128) comparing a Spiros DPI (Elan Pharmaceuticals; Dublin, Ireland) with a CFC MDI (Ventolin) estimated that these devices were approximately equipotent. This draws attention to the fact that differences in the relative amount of drug delivered to the lung depends not only on the general type of device used (DPI vs MDI) but also on the specific brand of device being compared (eg, Spiros DPI or Turbuhaler DPI).

Summary of RCT Results

* In the adult and pediatric outpatient population with asthma, available evidence comparing short-acting [[beta].sub.2]-agonist delivery by MDI and DPI show no differences in pulmonary function responses, symptom scores, or heart rate. This remains true when analysis is restricted to type 2b studies that estimate the doses required to produce equal levels of response (called dose-axis comparisons) [quality of evidence: good].

* In a limited number of type 2 studies comparing short-acting [[beta].sub.2]-agonists administered with an MDI to that with an MDI using a spacer or holding chamber, pulmonary function responses were found to be comparable (quality of evidence: low).

* The use of nebulizers for the delivery of short-acting [[beta].sub.2]-agonists in the outpatient setting has not been adequately studied in RCTs (quality of evidence: low).

Recommendations

1. For treatment of asthma in the outpatient setting, both the MDI, used with or without spacer/holding chamber, and the DPI are appropriate for the delivery of short-acting [[beta].sub.2]agonists. Quality of evidence: good; net benefit: substantial; strength of recommendation: A.

2. The appropriate selection of a particular type of aerosol delivery device in this setting includes the patient's ability to use the device correctly, the preferences of the patient for the device, the availability of the drug/device combination, the compatibility between the drug and delivery device, the lack of time or skills to properly instruct the patient in the use of the device or to monitor the appropriate use, the cost of the therapy, and the potential for reimbursement. Quality of evidence: low; net benefit: substantial; strength of recommendation: B.

Inhaled Corticosteroids for Asthma

Four trials (90,104,105,106,129) comparing the use of a DPI with that of an MDI plus spacer for the inhalation of inhaled corticosteroids in adult (90,104,105,129) asthmatic patients in the outpatient setting met the criteria for study inclusion (Table 18). No studies enrolling children were eligible for inclusion. To be able to accurately compare device performance and efficacy, we required that the same drug be delivered via MDI/ spacer and DPI, and this greatly limited the number of useable trials. In these four trials, the same dose of the same corticosteroid was used for the two delivery routes. The durations of these type 1 trials were relatively short. One trial was of 2 weeks duration, and the other three were of 4 weeks duration. Metaanalysis reported no difference for FE[V.sub.1], PEFR, or symptom scores (see Fig 9 on-line). Two of the trials addressed subject preference, and there was a significant preference for the DPI over the MDI/spacer combination (p < 0.01) [see Fig 10 on-line]. We deem the incidence of oral candidiasis to be a crucial outcome, and no trial addressed this issue. There were no randomized control trials that were eligible for study inclusion that addressed other device comparisons using inhaled corticosteroids (MDI vs MDI with spacer/holding chamber, and MDI used alone vs DPI).

Summary of RCT Results

* For adult patients with asthma in the outpatient setting, there are no differences in pulmonary function response or symptom scores when the same dose of the same corticosteroid is used in a DPI or MDI with spacer/holding chamber (quality of evidence: good).

* Two studies indicated a significant patient preference for use of the DPI over that of the MDI with spacer/holding chamber (quality of evidence: good).

* No RCT adequately addressed the incidence of oral candidiasis (quality of evidence: low).

Recommendations

1. For the treatment of asthma in the outpatient setting, both the MDI with a spacer/holding chamber and the DPI are appropriate devices for the delivery of inhaled corticosteroids. Quality of evidence: good; net benefit: substantial; strength of recommendation: A.

2. For outpatient asthma therapy, the selection of an appropriate aerosol delivery device for inhaled corticosteroids includes the patient's ability to use the device correctly, the preferences of the patient for the device, the availability of the drug/device combination, the compatibility between the drug and delivery device, the lack of time or skills to properly instruct the patient in the use of the device or monitor the appropriate use, the cost of therapy, and the potential for reimbursement. Quality of evidence: low; net benefit: substantial; strength of recommendation: B.

[[beta].sub.2]-Agonists and Anticholinergic Agents for COPD

Proving device efficacy can be difficult in COPD patients because the airway obstruction in such patients shows limited reversibility with drug therapy. Seven studies (130-136) comparing different delivery devices met the criteria for entry into this analysis (Table 19). Pooled analysis of these studies showed no evidence for superiority of any aerosol delivery device (nebulizer, MDI, or MDI with spacer in patients) for outpatients with COPD. While the data are quite limited for COPD patients, the experience in asthma patients supports the conclusions for COPD.

Turner et al, (50) in an acute setting adult trial, reported a significantly greater increase in heart rate for nebulizers compared to MDI without important differences in efficacy. Similar findings were reported by Berry et al (61) for inpatients with COPD, but data are lacking for COPD patients treated in the outpatient setting. In an outpatient study of patients with COPD, Pauwels et al (131) compared the use of an MDI and that of an MDI with a valved holding chamber following the inhalation of terbutaline, and reported that the MDI with holding chamber may be more effective than MDI alone. In an outpatient study of patients with asthma or COPD, Dorow and Hidinger et al (132) reported no differences between the use of an MDI and that of MDI with a valved holding chamber.

Device differences have not been adequately studied for combination bronchodilator therapy (eg, Combivent; Boehringer-Ingelheim; Ridgefield, CT) or for steroid preparations in outpatients with COPD. Delivery systems for long-acting bronchodilators (eg, salmeterol and formoterol) also have not been adequately studied in this patient population.

The selection of an aerosol delivery device for the treatment of outpatients with COPD is determined by the formulation, the needs of the patient, clinician biases, and reimbursement. Although use of an MDI (with spacer and mask if necessary) may produce similar results, nebulizers are often used in sicker and less cooperative patients.

Summary of RCT Results

* In the outpatient management of COPD patients with [[beta].sub.2]-agonist and anticholinergic agents, the available evidence shows no differences in pulmonary function responses between delivery devices (quality of evidence: good).

* Increases in heart rate were greater after the administration of albuterol by nebulizer than after administration by MDI (quality of evidence: good).

Recommendations

1. For the treatment of COPD in the outpatient setting, the MDI, with or without spacer/ holding chamber, the nebulizer, and the DPI are all appropriate for the delivery of inhaled [[beta].sub.2]-agonist and anticholinergic agents. Quality of evidence: good; net benefit: substantial; strength of recommendation: A.

2. For outpatient COPD therapy, the selection of an appropriate aerosol delivery device for inhaled [[beta].sub.2]-agonist and anticholinergic agents includes the patient's ability to use the device correctly, the preferences of the patient for the device, the availability of the drug/device combination, the compatibility between the drug and the delivery device, the lack of time or skills to properly instruct the patient in the use of the device or monitor its appropriate use, the cost of therapy, and the potential for reimbursement. Quality of evidence: low; net benefit: substantial; strength of recommendation: B.

DISCUSSION

The results of this systematic review of RCTs were essentially the same in each of the clinical settings evaluated above. None of the pooled metaanalyses (Tables 20 and 21, available on-line only) showed a significant difference between devices in any efficacy outcome in any patient group. Thus, the relative effectiveness of delivery methods does not provide a clear basis for selecting one device over another. This does not mean that the device choice for a specific patient does not seem to matter. In essence, this says that each of the devices studied can work equally well in that setting in patients who can use them appropriately. This is an important statement because most studies, especially in the outpatient setting, select for patients who are capable of using each of the devices with the appropriate technique or train patients to use the appropriate technique. The RCTs included in this systematic review do not provide much information about who is likely to use one device or another properly, nor do they address many other considerations that are important for choosing a delivery device for a specific patient in a specific clinical situation. These include the ability to use the device, patient preference, the availability of equipment, and cost. While the clinician is still left to select the method of delivery based on these other considerations, we have made general recommendations based on the results of the metaanalysis to guide the clinician in his/her selection of a delivery system. In addition, there are some obvious situations in which device selection clearly does matter. For example, in each of the clinical situations studied, there are some devices that were studied little or not at all. This appears to indicate a consensus that RCTs are not needed to determine that some devices are inappropriate for that clinical situation. For example, it is clear that infants and toddlers have virtually no chance of using an MDI (without spacer or holding chamber) or a DPI properly. Similarly, there are virtually no RCTs studying the MDI (without spacer or holding chamber) in the ED since most clinicians believe that the severe dyspnea experienced by many asthma patients in that setting would prevent them from using this device properly.

Consideration of the circumstances under which studies were performed is an important factor for interpreting the results of our systematic review. All of the RCTs performed in the acute care settings (ie, ED, inpatient unit, or ICU) are type 1 trials (ie, they were performed under conditions of actual clinical use in the ED, inpatient unit, or ICU). These studies are reassuring in that both a nebulizer and an MDI with a valved holding chamber can work well in that setting. Similarly, MDIs with a reverse-flow spacer can be successfully used in these settings but not in intubated patients, unless they incorporate an interface to the ventilator circuit. Similarly, studies of inhaled corticosteroid use in outpatients, while limited in number, are type 1 studies that are performed under conditions of actual clinical use. The results are reassuring in that each device can work well in patients who know how to use them correctly.

Studies of [[beta].sub.2]-agonist use for outpatient asthma and COPD are less reassuring since virtually all of these were type 2 studies that were performed under laboratory conditions rather than conditions of actual clinical use. The studies indicate that under ideal conditions and in patients who are successfully taught to use the devices correctly, the devices being compared can each deliver sufficient quantities of drug to the airway to elicit the same response. However, the relationship between these laboratory studies and the use of the device in patient's daily lives is not clear. Many of these studies were performed for regulatory purposes as part of the evaluation of new formulations. These kinds of studies are typically designed to demonstrate equivalence with an existing device. The doses used were typically selected to ensure this, particularly in the nebulizer vs MDI RCTs. (53,59,61,62) Thus, it is not surprising when these type 2 studies fail to show differences. It is also likely that the doses used in many of these laboratory-based studies produced responses that were near the plateau of the dose-response curve. Therefore, differences in drug delivery would not be reflected as a difference in response. However, these studies do not indicate that the device would perform equally well in more adverse, real-world situations, such as when a patient awakens at night with more bronchospasm and lower lung function than is typically studied in the clinical laboratory. (137,138) Furthermore, these studies routinely exclude patients who cannot correctly use the devices being compared. The results clearly apply just to the subpopulation of patients who can use the device effectively.

Differences in systemic adverse effects were present only between the nebulizer and the MDI with holding ehainber for albuterol delivery in the ED, and between the nebulizer and the MDI (used alone) for albuterol delivery in COPD outpatients. Heart rate was higher with nebulizer delivery. Vomiting was greater after nebulized albuterol administration than after albuterol administered by MDI with a valved holding chamber in children in the ED. These findings are most likely due to the larger doses of albuterol administered by the nebulizer compared to those administered by the MDI, resulting in greater systemic absorption.

We did not assess the power of individual studies a priori. Although it is likely that many studies were underpowered, the metaanalysis of these studies consistently fails to show a significant difference between devices. Moreover, our findings are consistent with those reported in other systematic reviews. (25-28,30,31,64,139) However, our interpretation of these results differs from those offered by authors of some of the reviews. Notably, Turner et al (25) concluded that because no clear differences between devices could be found in the systematic review of RCTs, cost alone should drive the choice between devices. This interpretation of the results of the systematic review was subsequently criticized in a number of letters to the editor, (140,141) although the review itself was not. In their review, Amirav and Newhouse (26) also found no differences in pulmonary function response to nebulized albuterol and albuterol administered by an MDI with holding chamber in children treated in the ED setting. They also interpreted their results as demonstrating that cost alone should be the determining factor for the choice of device. The interpretation of our systematic review as well as those of other authors in existence is open to debate. While we make general recommendations, they are based on the metaanalysis of the data from the RCTs considered. We have avoided making specific recommendations that are not directly supported by the RCT results.

How then, in practice, does one select an aerosol delivery device for the patient? In other words, what practical advice can be given for device selection when the best evidence shows no difference in outcomes between devices? In the following list, we review the important issues for clinicians to consider when selecting an aerosol delivery device.

When selecting an aerosol delivery device, the following questions should be considered:

1. In what devices is the desired drug available?

2. What device is the patient likely to be able to use properly, given the patient's age and the clinical setting?

3. For which device and drug combination is reimbursement available?

4. Which devices are the least costly?

5. Can all types of inhaled asthma/COPD drugs that are prescribed for the patient (eg, short-acting [beta]-agonist, corticosteroid, anticholinergic, and long-acting [beta]-agonist) be delivered with the same type of device (eg, nebulizer, manually actuated MDI, MDI with spacer/ holding chamber, or breath-actuated device [ie, automatically activated MDI or DPI])? Using the same type of device for all inhaled drugs may facilitate patient teaching and decrease the chance for confusion among devices that require different inhalation techniques.

6. Which devices are the most convenient for the patient, family (outpatient use), or medical staff (acute care setting) to use, given the time required for drug administration and device cleaning, and the portability of the device?

7. How durable is the device?

8. Does the patient or clinician have any specific device preferences?

Finally, whichever device is chosen, it is clear that proper patient education on its use is critical and that the assessment of inhalation technique should be part of subsequent visits to the physician. (142) Therefore, physicians, respiratory therapists, and nurses caring for patients with respiratory diseases should be familiar with issues related to performance and with the correct use of aerosol delivery devices. Patients must be adequately instructed in the correct use of aerosol delivery devices. If the selected delivery device should fail to provide satisfactory treatment or result in un acceptable side effects for the patient, both clinician and patient should recognize that there are other effective options.

SUMMARIES AND RESULTS

Aerosol Delivery of Short-Acting [[beta].sub.2]-Agonists in the Hospital ED

Summary of RCT Results:

* The delivery of [[beta].sub.2]-agonists in the ED setting by nebulizers or MDIs with holding chambers (eg, AeroChamber, Volumatic, or InspirEase) is equally effective for improving pulmonary function and reducing symptoms of acute asthma in both adult and pediatric patients (quality of evidence: good).

* The delivery of [[beta].sub.2]-agonists in the ED setting by DPI (eg, Rotahaler or Turbuhaler) has been inadequately studied, but trials in adults have suggested DPIs may be as effective as nebulizers or MDIs with spacer/holding chambers (quality of evidence: low).

* Nebulizer use in the ED setting is associated with greater increases in heart rate than with the use of an MDI with spacer/holding chamber, suggesting that a larger systemically absorbed dose is administered by nebulizers (quality of evidence: good).

Recommendations:

1. Both the nebulizer and MDI with spacer/ holding chamber are appropriate for the delivery of short-acting [[beta].sub.2]-agonists in the ED. Quality of evidence: good; net benefit: substantial; strength of recommendation: A.

2. Because data for DPIs are limited, and high quality data for standard MDIs (without spacer/ holding chamber) and breath-actuated MDIs are unavailable, we are unable to recommend the use of these devices in the ED until more information is available. Quality of evidence: low; net benefit: none; strength of recommendation: I.

3. Many factors would lead the clinician to appropriately select a particular type of aerosol de livery device in this setting. These factors include the patient's ability to use the device correctly, the preferences of the patient for the device, the unavailability of an appropriate drug/device combination, the compatibility between the drug and delivery device, the lack of time or skills to properly instruct the patient in the use of the device or to monitor the appropriate use, and the cost of therapy. Quality of evidence: low; net benefit: substantial; strength of recommendation: B.

Aerosol Delivery of Short-Acting [[beta].sub.2]-Agonists in the Inpatient Hospital Setting

Summary of RCT Results:

* In the inpatient setting, the available evidence suggests that there is no difference in the pulmonary function response between using a nebulizer and using an MDI with a spacer/holding chamber for administering short-acting [[beta].sub.2]-agonist therapy (quality of evidence: good).

Recommendations:

1. Both nebulizers and MDIs with spacer/holding chambers are appropriate for use in the inpatient setting. Quality of evidence: good; net benefit: substantial; strength of recommendation: A.

2. Because the data for DPIs, standard MDIs without spacer/holding chambers, and breath-actuated MDIs have been inadequately studied in this setting, we are unable to recommend the use of these devices in patients requiring hospitalization for asthma or COPD until more information is available. Quality of evidence: low; net benefit: none; strength of recommendation: I.

3. Many factors would lead the clinician to appropriately select a particular type of aerosol delivery device in this setting. These include the patient's inability to use the device correctly, the preferences of the patient for the device, the unavailability of the drug/device combination, the compatibility between the drug and the delivery device, the lack of time or skills to properly instruct the patient in the use of the device or in monitoring the appropriate use, and the cost of therapy. Quality of evidence: low; net benefit: substantial; strength of recommendation: B.

Intermittent vs Continuous Nebulizer Delivery of [[beta].sub.2]-Agonists

Summary of RCT Results:

* Pulmonary function and asthma symptom scores show similar benefits for continuous and intermittent nebulization of short-acting [[beta].sub.2]-agonists (quality of evidence: good).

* The time requirements for staff administration and maintenance of the therapy are less for continuous nebulization than for intermittent nebulization (quality of evidence: good).

* Adverse effects of [[beta].sub.2]-agonists are similar for continuous and intermittent nebulization of [[beta].sub.2]-agonists (quality of evidence: good).

* The effects of continuous vs intermittent nebulization of [[beta].sub.2]-agonists on hospital admission rate from the ED, hospital length of stay, and cost of care have not been adequately studied (quality of evidence: low).

Recommendation:

1. Frequent intermittent nebulization and continuous nebulization are both appropriate alternatives in severely dyspneic patients in the ED or ICU. Quality of evidence: good; net benefit: substantial; strength of recommendation: A.

Aerosolized [[beta].sub.2]-Agonists in Patients Receiving Mechanical Ventilation

Summary of RCT Results:

* In children and adults receiving mechanical ventilation, the outcomes of [[beta].sub.2]-agonist administration using an MDI with or without a spacer/holding chamber are no different than those observed following [[beta].sub.2]-agonist administration with a nebulizer (quality of evidence: fair).

* High doses of [[beta].sub.2]-agonists administered with a nebulizer are associated with a higher incidence of tachycardia and premature heart beats in mechanically ventilated patients, but there is no difference in adverse effects observed after the administration of albuterol with an MDI compared to those observed after the administration of the drug with a nebulizer (quality of evidence: fair).

* There is insufficient evidence to guide the choice of MDI or nebulizer for patients receiving NPPV (quality of evidence: low).

Recommendations:

1. Both nebulizers and MDIs can be used to deliver [[beta].sub.2]-agonists to mechanically ventilated patients. Quality of evidence: fair; net benefit: substantial; strength of recommendation: A.

2. Careful attention to details of the technique employed for administering drugs by MDI or nebulizer to mechanically ventilated patients is critical, since multiple technical factors may have clinically important effects on the efficiency of aerosol delivery. Quality of evidence: low; net benefit: substantial; strength of recommendation: B.

Short-Acting [[beta].sub.2]-Agonists for Asthma in the Outpatient Setting

Summary of RCT Results:

* In the adult and pediatric outpatient population with asthma, available evidence comparing short-acting [[beta].sub.2]-agonist delivery by MDI and DPI show no differences in pulmonary function responses, symptom scores, or heart rate. This remains true when analysis is restricted to type 2b studies that estimate the doses required to produce equal levels of response (called dose-axis comparisons) [quality of evidence: good].

* In a limited number of type 2 studies comparing short-acting [[beta].sub.2]-agonists administered with an MDI to that with an MDI using a spacer or holding chamber, pulmonary function responses were found to be comparable (quality of evidence: low).

* The use of nebulizers for the delivery of short-acting [[beta].sub.2]-agonists in the outpatient setting has not been adequately studied in RCTs (quality of evidence: low).

Recommendations:

1. For treatment of asthma in the outpatient setting, both the MDI, used with or without spacer/holding chamber, and the DPI are appropriate for the delivery of short-acting [[beta].sub.2]-agonists. Quality of evidence: good; net benefit: substantial; strength of recommendation: A.

2. The appropriate selection of a particular type of aerosol delivery device in this setting includes the patient's ability to use the device correctly, the preferences of the patient for the device, the availability of the drug/device combination, the compatibility between the drug and delivery device, the lack of time or skills to properly instruct the patient in the use of the device or to monitor the appropriate use, the cost of the therapy, and the potential for reimbursement. Quality of evidence: low; net benefit: substantial; strength of recommendation: B.

Inhaled Corticosteroids for Asthma

Summary of RCT Results:

* For adult patients with asthma in the outpatient setting, there are no differences in pulmonary function response or symptom scores when the same dose of the same corticosteroid is used in a DPI or MDI with spacer/holding chamber (quality of evidence: good).

* Two studies indicated a significant patient preference for use of the DPI over that of the MDI with spacer/holding chamber (quality of evidence: good).

* No RCT adequately addressed the incidence of oral candidiasis (quality of evidence: low).

Recommendations:

1. For the treatment of asthma in the outpatient setting, both the MDI with a spacer/holding chamber and the DPI are appropriate devices for the delivery of inhaled corticosteroids. Quality of evidence: good; net benefit: substantial; strength of recommendation: A.

2. For outpatient asthma therapy, the selection of an appropriate aerosol delivery device for inhaled corticosteroids includes the patient's ability to use the device correctly, the preferences of the patient for the device, the availability of the drug/device combination, the compatibility between the drug and delivery device, the lack of time or skills to properly instruct the patient in the use of the device or monitor the appropriate use, the cost of therapy, and the potential for reimbursement. Quality of evidence: low; net benefit: substantial; strength of recommendation: B.

[[beta].sub.2]-Agonists and Anticholinergic Agents for COPD

Summary of RCT Results:

* In the outpatient management of COPD patients with [[beta].sub.2]-agonist and anticholinergic agents, the available evidence shows no differences in pulmonary function responses between delivery devices (quality of evidence: good).

* Increases in heart rate were greater after the administration of albuterol by nebulizer than after administration by MDI (quality of evidence: good).

Recommendations:

1. For the treatment of COPD in the outpatient setting, the MDI, with or without spacer/holding chamber, the nebulizer, and the DPI are all appropriate for the delivery of inhaled [[beta].sub.2]-agonist and anticholinergic agents. Quality of evidence: good; net benefit: substantial; strength of recommendation: A.

2. For outpatient COPD therapy, the selection of an appropriate aerosol delivery device for inhaled [[beta].sub.2]-agonist and anticholinergic agents includes the patient's ability to use the device correctly, the preferences of the patient for the device, the availability of the drug/device combination, the compatibility between the drug and the delivery device, the lack of time or skills to properly instruct the patient in the use of the device or monitor its appropriate use, the cost of therapy, and the potential for reimbursement. Quality of evidence: low; net benefit: substantial; strength of recommendation: B.

Device Selection

When selecting an aerosol delivery device, the following questions should be considered:

1. In what devices is the desired drug available?

2. What device is the patient likely to be able to use properly, given the patient's age and the clinical setting?

3. For which device and drug combination is reimbursement available?

4. Which devices are the least costly?

5. Can all types of inhaled asthma/COPD drugs that are prescribed for the patient (eg, short-acting [beta]-agonist, corticosteroid, anticholinergic, and long-acting [beta]-agonist) be delivered with the same type of device (eg, nebulizer, manually actuated MDI, MDI with spacer/ holding chamber, or breath-actuated device [ie, automatically activated MDI or DPI])? Using the same type of device for all inhaled drugs may facilitate patient teaching and decrease the chance for confusion among devices that require different inhalation techniques.

6. Which devices are the most convenient for the patient, family (outpatient use), or medical staff (acute care setting) to use, given the time required for drug administration and device cleaning, and the portability of the device?

7. How durable is the device?

8. Does the patient or clinician have any specific device preferences?

ACKNOWLEDGMENT: The authors thank Angela Eady and Lauren Griffith (Department of Clinical Epidemiology and Biostatistics and Medicine, McMaster University, Hamilton, ON, Canada) and James B Fink, MS, Fellow, Respiratory Science, Aerogen, Inc (Mountain View, CA).

REFERENCES

(1) Newhouse MT, Dolovich MB. Control of asthma by aerosols. N Engl J Med 1986; 315:870-874

(2) National Asthma Education and Prevention Program. Expert panel report 2: guidelines for the diagnosis and management of asthma. Bethesda, MD: National Heart, Lung, and Blood Institute, April 1997; NIH Publication No. 97-4051

(3) National Heart, Lung, and Blood Institute/World Health Organization. Global strategy for the diagnosis, management, and prevention of chronic obstructive pulmonary disease: National Heart, Lung, and Blood Institute and World Health Organization Global Initiative for Chronic Obstructive Lung Disease (GOLD); workshop summary. Am J Respir Crit Care Med 2001; 163:1256-1276

(4) Dolovich M, Ruffin RE, Roberts R, et al. Optimal delivery of aerosols from metered dose inhalers. Chest 1981; 80(suppl):911-915

(5) Newman SP, Pavia D, Clarke SW. How should a pressurized beta-adrenergic bronchodilator be inhaled? Eur J Respir Dis 1981; 62:3-21

(6) Crompton GK. Problems patients have using pressurized aerosol inhalers. Eur J Respir Dis 1982; 63(suppl):101-104

(7) De Blaquiere P, Christensen DB, Carter WB, et al. Use and misuse of metered-dose inhalers by patients with chronic lung disease: a controlled, randomized trial of two instruction methods. Am Rev Respir Dis 1989:140:910-916

(8) Kamps AW, van Ewijk B, Roorda RJ, et al. Poor inhalation technique, even after inhalation instructions, in children with asthma. Pediatr Pulmonol 2000:29:39-42

(9) Guidry CG, Brown WD, Stogner SW, et al. Incorrect use of metered dose inhalers by medical personnel. Chest 1992; 101:31-33

(10) Hanania NA, Wittman R, Kesten S, et al. Medical personnel's knowledge of and ability to use inhaling devices: metered-dose inhalers, spacing chambers, and breath- actuated dry powder inhalers. Chest 1994; 105:111-116

(11) Kesten S, Zive K, Chapman KR. Pharmacist knowledge and ability to use inhaled medication delivery systems. Chest 1993: 104:1737-1742

(12) Lindgren S, Bake B, Larsson S. Clinical consequences of inadequate inhalation technique in asthma therapy. Eur J Respir Dis 1987; 70:93-98

(13) McFadden ER Jr. Improper patient techniques with metered dose inhalers: clinical consequences and solutions to misuse. J Allergy Clin Immunol 1995; 96:278-282

(14) Freedman T. Medihaler therapy for bronchial asthma: a new type of aerosol therapy. Postgrad Med J 1956; 20:667-673

(15) Mercer TT. Production of therapeutic aerosols: principles and techniques. Chest 1981; 80:S813-S817

(16) Muers MF. Overview of nebuliser treatment. Thorax 1997; 52:S25-S30

(17) Bell JH, Hartley PS, Cox JSG. Dry powder aerosols: I. A new powder inhalation device. J Pharm Sci 1971; 60:1559-1564

(18) Corr D, Dolovich M, McCormack D, et al. Design and characteristics of a portable breath-actuated particle size selective medical aerosol inhaler. J Aerosol Sci 1982; 13:1-7

(19) Moren F. Drug deposition of pressurized inhalation aerosols: I. Influence of actuator tube design. Int J Pharm 1978; 1:205-212

(20) Newman SP, Moren F, Pavia D, et al. Deposition of pressurized suspension aerosols inhaled through extension devices. Am Rev Respir Dis 1981; 124:317-320

(21) Tobin MJ, Jenouri G, Danta I, et al. Response to bronchodilator drug administration by a new reservoir aerosol delivery system and a review of other auxiliary delivery systems. Am Rev Respir Dis 1982; 126:670-675

(22) Leach CL. Approaches and challenges to use freon propellant replacements. Aerosol Sci Technol 1995; 22:328-334

(23) Dolovich M. New delivery systems and propellants. Can Respir J 1999; 6:290-295

(24) Pedersen S. How to use a rotahaler. Arch Dis Child 1986; 61:11-14

(25) Turner MO, Patel A, Ginsburg S, et al. Bronchodilator delivery in acute airflow obstruction: a meta-analysis. Arch Intern Med 1997; 157:1736-1744

(26) Amirav I, Newhouse MT. Metered-dose inhaler accessory devices in acute asthma: efficacy and comparison with nebulizers; a literature review. Arch Pediatr Adolesc Med 1997; 151:876-882

(27) Bach PB, Brown C, Gelfand SE, et al. Management of acute exacerbations of chronic obstructive pulmonary disease: a summary and appraisal of published evidence. Ann Intern Med 2001: 134:600-620

(28) Cates CJ, Rowe BH, Bara A. Holding chambers versus nebulisers for beta-agonist treatment of acute asthma. Cochrane Database Syst Rev (database online). Issue 2, 2002

(29) Cates C. Spacers and nebulisers for the delivery of beta-agonists in non-life-threatening acute asthma. Respir Med 2003; 97:762-769

(30) Ram FSF, Wright J, Brocklebank D, et al. Systematic review of clinical effectiveness of pressurised metered dose inhalers versus other hand held inhaler devices for delivering [[beta].sub.2]-agonists bronchodilators in asthma. BMJ 2001; 323:901-905

(31) Ram FS, Brocklebank DM, Muers M, et al. Pressurised metered-dose inhalers versus all other hand-held inhalers devices to deliver bronchodilators for chronic obstructive pulmonary disease. Cochrane Database Syst Rev (database online). Issue 1, 2002

(32) Ram FS, Brocklebank DM, White J, et al. Pressurised metered dose inhalers versus all other hand-held inhaler devices to deliver [[beta].sub.2] agonist bronchodilators for non-acute asthma. Cochrane Database Syst Rev (database online). Issue 1, 2002

(33) Guyatt G, Hayward R, Richardson WS, et al. Moving from evidence to action. In: Guyatt G, Rennie D, eds. The user's guides to the medical literature: a manual for evidence-based clinical practice. Chicago, IL: AMA Publications, 2002

(34) Fleiss JL. The statistical basis of meta-analysis. Star Methods Med Res 1993; 2:121-145

(35) Hedges LV, Olkin I. Statistical methods for meta-analysis. San Diego, CA: Academic Press, 1985

(36) Ahrens BC. On comparing inhaled [beta] adrenergic agonists. Ann Allergy 1991; 67:296-298

(37) Batra V, Sethi GR, Sachdev HP. Comparative efficacy of jet nebulizer and metered dose inhaler with spacer device in the treatment of acute asthma. Indian Pediatr 1997; 34:497-503

(38) Chou KJ, Cunningham SJ, Crain EF. Metered-dose inhalers with spacers vs nebulizers for pediatric asthma. Arch Pediatr Adolesc Med 1995; 149:201-205 [published erratum appears in Arch Pediatr Adolesc Med 1995; 149:545]

(39) Lin YZ, Hsieh KH. Metered dose inhaler and nebuliser in acute asthma. Arch Dis Child 1995; 72:214-218

(40) Ploin D, Chapuis FR, Stamm D, et al. High-dose albuterol by metered-dose inhaler plus a spacer device versus nebulization in preschool children with recurrent wheezing: a double-blind, randomized equivalence trial. Pediatrics 2000; 106:311-317

(41) Robertson CF, Norden MA, Fitzgerald DA, et al. Treatment of acute asthma: salbutamol via jet nebuliser vs spacer and metered dose inhaler. J Paediatr Child Health 1998; 34:142-146

(42) Rubilar L, Castro-Rodriguez JA, Girardi G. Randomized trial of salbutamol via metered-dose inhaler with spacer versus nebulizer for acute wheezing in children less than 2 years of age. Pediatr Pulmonol 2000; 29:264-269

(43) Schuh S, Johnson DW, Stephens D, et al. Comparison of albuterol delivered by a metered dose inhaler with spacer versus a nebulizer in children with mild acute asthma. J Pediatr 1999; 135:22-27

(44) Williams JR, Bothner JP, Swanton RD. Delivery of albuterol in a pediatric emergency department. Pediatr Emerg Care 1996; 12:263-267

(45) Colacone A, Afilalo M, Wolkove N, et al. A comparison of albuterol administered by metered dose inhaler (and holding chamber) or wet nebulizer in acute asthma. Chest 1993; 104:835-841

(46) Idris AH, McDermott MF, Raucci JC, et al. Emergency department treatment of severe asthma: metered-dose inhaler plus holding chamber is equivalent in effectiveness to nebulizer. Chest 1993; 103:665-672

(47) Raimondi AC, Schottlender J, Lombardi D, et al. Treatment of acute severe asthma with inhaled albuterol delivered via jet nebulizer, metered dose inhaler with spacer, or dry powder. Chest 1997; 97:24-28

(48) Rodrigo G, Rodrigo C. Comparison of salbutalnol delivered by nebulizer or metered-dose inhaler with a pear-shaped spacer in acute asthma. Curr Ther Res Clin Exp 1993; 54:797-808

(49) Salzman GA, Steele MT, Pribble JP, et al. Aerosolized metaproterenol in the treatment of asthmatics with severe airflow obstruction: comparison of two delivery methods. Chest 1989; 95:1017-1020

(50) Turner JR, Corkery KJ, Eckman D, et al. Equivalence of continuous flow nebulizer and metered-dose inhaler with reservoir bag for treatment of acute airflow obstruction. Chest 1988; 93:476-481

(51) Levitt MA, Gambrioli EF, Fink JB. Comparative trial of continuous nebulization versus metered dose inhaler in the treatment of acute bronchospasm. Ann Emerg Med 1995; 26:273-277

(52) Mandelberg A, Chen E, Noviski N, et al. Nebulized wet aerosol treatment in emergency department: is it essential? Comparison with large spacer device for metered-dose inhaler. Chest 1997; 112:1501-1505

(53) Summer W, Elston R, Tharpe L, et al. Aerosol bronchodilator delivery methods: relative impact on pulmonary function and cost of respiratory care. Arch Intern Med 1989; 149:618-623

(54) Nana A, Youngchaiyud P, Maranetra N, et al. [[beta].sub.2]-agonists administered by a dry powder inhaler can be used in acute asthma. Respir Med 1998; 92:167-172

(55) Tonnesen F, Laursen LC, Evald T, et al. Bronchodilating effect of terbutaline powder in acute severe bronchial obstruction. Chest 1994; 105:697-700

(56) Delgado A, Chou KJ, Silver E, et al. Nebulizers vs metered-dose inhalers with spacers for bronchodilator therapy to treat wheezing in children aged 2 to 24 months in a pediatric emergency department. Arch Pediatr Adolesc Med 2003; 157:76-80

(57) Campbell IA, Colman SB, Mao JH, et al. An open, prospective comparison of beta2 agonists given via nebuliser, Nebuhaler, or pressurised inhaler by ambulance crew as emergency treatment. Thorax 1995; 50:79-80

(58) Parkin PC, Saunders NR, Diamond SA, et al. Randomised trial spacer v nebuliser for acute asthma. Arch Dis Child 1995; 72:239-240

(59) Jasper AC, Mohsenifar Z, Kaban S, et al. Cost-benefit comparison of aerosol bronchodilator delivery methods in hospitalized patients. Chest 1987; 91:614-618

(60) Fuglsang G, Pedersen S. Comparison of Nebuhaler and nebulizer treatment of acute severe asthma in children. Eur J Respir Dis 1986; 69:109-113

(61) Berry RB, Shinto RA, Wong FH, et al. Nebulizer vs spacer for bronchodilator delivery in patients hospitalized for acute exacerbations of COPD. Chest 1989; 96:1241-1246

(62) Ruggins NR, Milner AD, Swarbrick A. An assessment of a new breath actuated inhaler device in acutely wheeze children. Arch Dis Child 1993; 68:477-480

(63) Dewar AL, Stewart A, Cogswell JJ, et al. A randomised controlled trial to assess the relative benefits of large volume spacers and nebulisers to treat acute asthma in hospital. Arch Dis Child 1999; 80:421-423

(64) Rodrigo GJ, Rodrigo C. Continuous vs intermittent [beta]-agonists in the treatment of acute adult asthma: a systematic review with meta-analysis. Chest 2002; 122:160-165

(65) Khine H, Fuchs SM, Saville AL. Continuous vs intermittent nebulized albuterol for emergency management of asthma. Acad Emerg Med 1996; 3:1019-1024

(66) Shrestha M, Bidadi K, Gourlay S, et al. Continuous vs intermittent albuterol, at high and low doses, in the treatment of severe acute asthma in adults. Chest 1996; 109: 42-47

(67) Reisner C, Kotch A, Dworkin G. Continuous versus frequent intermittent nebulization of albuterol in acute asthma: a randomized, prospective study. Ann Allergy Asthma Immunol 1995; 75:41-47

(68) Lin RY, Sauter D, Newman T, et al. Continuous versus intermittent albuterol nebulization in the treatment of acute asthma. Ann Emerg Med 1993; 22:1847-1853

(69) Rudnitsky GS, Eberlein RS, Schoffstall JM, et al. Comparison of intermittent and continuously nebulized albuterol for treatment of asthma in an urban emergency department. Ann Emerg Med 1993; 22:1842-1846

(70) Papo MC, Frank J, Thompson AE. A prospective, randomized study of continuous versus intermittent nebulized albuterol for severe status asthmaticus in children. Crit Care Med 1993; 21:1479-1486

(71) Torres A Jr, Anders M, Anderson P, et al. Efficacy of metered-dose inhaler administration of albuterol in intubated infants. Chest 1997; 112:484-490

(72) Gay PC, Patel HG, Nelson SB, et al. Metered dose inhalers for bronchodilator delivery in intubated, mechanically ventilated patients. Chest 1991; 99:66-71

(73) Manthous CA, Hall JB, Schmidt GA, et al. Metered-dose inhaler versus nebulized albuterol in mechanically ventilated patients. Am Rev Respir Dis 1993; 148:1567-1570

(74) Diot P, Morra L, Smaldone GC. Albuterol delivery in a model of mechanical ventilation: comparison of metered-dose inhaler and nebulizer efficiency. Am J Respir Crit Care Med 1995; 152:1391-1394

(75) Dhand R, Tobin MJ. Inhaled bronchodilator therapy in mechanically ventilated patients. Am J Respir Crit Care Med 1997; 156:3-10

(76) Duarte AG, Momii K, Bidani A. Bronchodilator therapy with metered-dose inhaler and spacer versus nebulizer in mechanically ventilated patients: comparison of magnitude and duration of response. Respir Care 2000; 45:817-823

(77) Dolovich MB. Influence of inspiratory flow rate, particle size, and airway caliber on aerosolized drug delivery to the lung. Respir Care 2000; 45:597-608

(78) Hughes JM, Saez J. Effects of nebulizer mode and position in a mechanical ventilator circuit on dose efficiency. Respir Care 1987; 32:1131-1135

(79) O'Doherty MJ, Thomas SH, Page CJ, et al. Delivery of a nebulized aerosol to a lung model during mechanical ventilation: effect of ventilator settings and nebulizer type, position, and volume of fill. Am Rev Respir Dis 1992; 146:383-388

(80) O'Riordan TG, Greco MJ, Perry RJ, et al. Nebulizer function during mechanical ventilation. Am Rev Respir Dis 1992; 145:1117-1122

(81) McPeck M, O'Riordan TG, Smaldone GC. Choice of mechanical ventilator: influence on nebulizer performance. Respir Care 1993; 38:887-895

(82) Good M, Fink JB, Dhand R, et al. Improvement in aerosol delivery with helium-oxygen mixtures during mechanical ventilation. Am J Respir Crit Care Med 2001; 163:109-114

(83) Mouloudi E, Prinianakis G, Kondili E, et al. Bronchodilator delivery by metered dose inhaler in mechanically ventilated patients: influence of flow pattern. Eur Respir J 2000; 16:263-268

(84) Mouloudi E, Prinianakis G, Kondili E, et al. Effect of inspiratory flow rate on [[beta].sub.2]-agonist induced bronchodilation in mechanically ventilated COPD patients. Intensive Care Med 2001; 27:42-46

(85) Mouloudi E, Katsanoulas K, Anastasaki M, et al. Bronchodilator delivery by metered-dose inhaler in mechanically ventilated COPD patients: influence of tidal volume. Intensive Care Med 1999; 25:1215-1221

(86) Mouloudi E, Katsanoulas K, Anastasaki M, et al. Bronchodilator delivery by metered-dose inhaler in mechanically ventilated COPD patients: influence of end-inspiratory pause. Eur Respir J 1998; 12:165-169

(87) Fuller HD, Dolovich MB, Turpie FH, et al. Efficiency of bronchodilator aerosol delivery to the lungs from the metered dose inhaler in mechanically ventilated patients: a study comparing four different actuator devices. Chest 1994; 105:214-218

(88) Pollack CV Jr, Fleisch KB, Dowsey K. Treatment of acute bronchospasm with beta-adrenergic agonist aerosols delivered by a nasal bilevel positive airway pressure circuit. Ann Emerg Med 1995; 26:552-557

(89) Nava S, Karakurt S, Rampulla C, et al. Salbutamol delivery during non-invasive mechanical ventilation in patients with chronic obstructive pulmonary disease: a randomised, controlled study. Intensive Care Med 2001; 27:1627-1635

(90) Boe J, Stiksa G, Svensson K, et al. New method of evaluating patient preference for different inhalation delivery systems. Ann Allergy 1992; 68:255-260

(91) Osterman K, Norborg AM, Stahl E. A multiple dose powder inhaler (Turbuhaler) compared with a conventional aerosol: an acceptance study in asthmatics. Allergy 1989; 44:294-297

(92) Johnsen CR, Weeke ER. Turbuhaler: a new device for dry powder terbutaline inhalation. Allergy 1988; 48:392-395

(93) Persson G, Gruvstad E, Stahl E. A new multiple dose powder inhaler, (Turbuhaler), compared with a pressurized inhaler in a study of terbutaline in asthmatics. Eur Respir J 1988; 1:681-684

(94) Lahdensuo A, Sovijarvi A, Muittari A. Inhaled powder and aerosol salbutamol in methacholine-induced bronchial obstruction. Eur J Respir Dis Suppl 1983; 128:515-517

(95) Svedmyr N, Lofdahl CG, Svedmyr K. The effect of powder aerosol compared to pressurized aerosol. Eur J Respir Dis Suppl 1982; 119:81-82

(96) Kiviranta K. Fenoterol inhalation powder and aerosol in the treatment of asthma. Allergy 1985; 40:305-307

(97) Bundgaard A, Schmidt A. Pretreatment of exercise-induced asthma with sequential inhalations of fenoterol as aerosol and as powder (first of two parts). Eur J Respir Dis Suppl 1983; 130:59-65

(98) Dirksen H, Groth S. Fenoterol inhalation powder as an alternative to treatment with the metered dose inhaler. Eur J Respir Dis Suppl 1983; 130:48-53

(99) Bundgaard A, Schmidt A. Pretreatment of exercise-induced asthma by fenoterol delivered as inhalation powder and pressurized aerosol. Ann Allergy 1982; 48:36-39

(100) Nelson HS, Loffert DT. Comparison of the bronchodilator response to albuterol administered by the OptiHaler, the AeroChamber, or by metered dose inhaler alone. Ann Allergy 1994; 72:337-340

(101) Tammivaara R, Aalto E, Lehtonen K, et al. Comparison era novel salbutamol multidose powder inhaler with a salbutamol metered dose inhaler in patients with asthma. Curr Ther Res Clin Exp 1997; 58:734-744

(102) Mathieu M, Goldman M, Lellouche N, et al. Kinetics of action of salbutamol inhaled from a metered dose inhaler (MDI) and a "diskhaler". Eur J Clin Pharmacol 1992; 42:435-438

(103) Vilsvik J, Schaanning J, Stahl E, et al. Comparison between Bricanyl Turbuhaler and ventolin metered dose inhaler in the treatment of exercise-induced asthma in adults. Ann Allergy 1991; 67:315-318

(104) Nieminen MM, Lahdensuo A. Inhalation treatment with budenoside in asthma: a comparison of Turbuhaler and metered dose inhalation with Nebuhaler. Acta Ther 1995; 21:179-192

(105) Vidgren P, Silvasti M, Ponkkula A, et al. Easyhaler powder inhaler--a new alternative in the anti-inflammatory treatment of asthma. Acta Therapeutica 1994; 20(3-4):117-131

(106) Vidgren M, Silvasti M, Korhonen P, et al. Clinical equivalence of a novel multiple dose powder inhaler versus a conventional metered dose inhaler on bronchodilating effects of salbutamol. Arzneimittelforschung 1995; 45:44-47

(107) Jackson L, Stahl E, Holgate ST. Terbutaline via pressurised metered dose inhaled (P-MDI) and Turbuhaler in highly reactive asthmatic patient. Eur Respir J 1994; 7:1598-1601

(108) Lindsay DA, Russell NL, Thompson JE, et al. A multicentre comparison of the efficacy of terbutaline Turbuhaler and salbutamol pressurized metered close inhaler in hot, humid regions. Eur Respir J 194; 7:342-345

(109) Haahtela T, Vidgren M, Nyberg A, et al. A novel multiple dose powder inhaler: salbutamol powder and aerosol give equal bronchodilatation with equal doses. Ann Allergy 1994; 72:178-182

(110) Lantos A, Tarjan E, Varnai Z, et al. Use of Talcum 1-mg inhalation aerosol in bronchial asthma patient. Ther Hung 1993; 41:146-149

(111) Zainudin BMZ, Biddiscombe M, Tolfree SEJ, et al. Comparison of bronchodilator responses and deposition patterns of salbutamol inhaled from a pressurised metered dose inhaler, as a dry powder, and as a nebulised solution. Thorax 1990; 45:469-473

(112) Geoffrey P, Lalonde RL, Ahrens R, et al. Clinical comparability of albuterol delivered by the breath-actuated inhaler (Spiros) and albuterol by MDI in patients with asthma. Ann Allergy Asthma Immunol 1999; 82:377-382

(113) Nieminen MM, Vidgren M, Laurikainen K, et al. Easyhaler, a novel multiple dose powder inhaler: clinically equivalent to salbutamol metered dose inhaler and easier to us. Respiration 1994; 61:37-41

(114) Nelson H, Kemp JP, Bieler S, et al. Comparative efficacy and safety of albuterol sulfate Spires inhaler and albuterol metered-dose inhaler in asthma. Chest 1999; 115:329-335

(115) Bauer K, Dietersdorfer F, Sertl K, et al. Pharmacodynamic effects of inhaled dry powder formulations of fenoterol and colforsin in asthma. Clin Pharmacol Ther 1993; 53:76-83

(116) Lahdensuo A, Muittari A. Bronchodilator effects of a fenoterol metered dose inhaler and fenoterol powder in asthmatics with poor inhaler technique. Eur J Respir Dis 1986; 68:332-335

(117) Hirsch T, Peter-Kern M, Koch R, et al. Influence of inspiratory capacity on bronchodilatation via Turbuhaler or pressurized metered-dose inhaler in asthmatic children: a comparison. Respir Med 1997; 91:341-346

(118) Svenonius E, Arborelius M, Wiberg R, et al. A comparison of terbutaline inhaled by Turbuhaler and by a chlorofluorocarbon (CFC) inhaler in children with exercise-induced asthma. Allergy 1994; 46:408-412

(119) Chambers S, Dunbar J, Taylor B. Inhaled powder compared with aerosol administration of fenoterol in asthmatic children. Arch Dis Child 1980; 80:73-74

(120) Reiser J, Frame MH, Warner JO. The potential value of a 750-ml spacer for the administration of inhaled corticosteroids to children. Pediatric Pulmonol 1986; 2:237-243

(121) Bloomfield P, Crompton GK, Winsey NJ. A tube spacer to improve inhalation of drugs from pressurised aerosols. BMJ 1979; 2:1479

(122) Pedersen JZ, Bundgaard A. Comparative efficacy of different methods of nebulising terbutaline. Eur J Clin Pharmacol 1983; 25:739-742

(123) Madsen EB, Bundgaard A, Hidinger KG. Cumulative dose-response study comparing terbutaline pressurized aerosol administered via a pearshaped spacer and terbutaline in a nebulized solution. Eur J Clin Pharmacol 1982; 23:27-30

(124) Blake KV, Hoppe M, Harman E, et al. Relative amount of albuterol delivered to lung receptors from a metered-dose inhaler and nebulizer solution: bioassay by histamine bronchoprovocation. Chest 1992; 101:309-315

(125) Wong AG, O'Byrne PM, Lindbladh C, et al. Dose-response protective effect of salbutamol on methacholine airway responsiveness using pressurized metered dose inhalers and Turbuhalers. Can Respir J 1998; 5:119-123

(126) Lofdahl CG, Andersson L, Bondesson E, et al. Differences in bronchodilating potency of salbutamol in Turbuhaler as compared with a pressurized metered-dose inhaler formulation in patients with reversible airway obstruction. Eur Respir J 1997; 10:2474-2478

(127) Bondesson E, Friberg K, Soliman S, et al. Safety and efficacy of a high cumulative dose of salbutamol inhaled via Turbuhaler or via a pressurized metered-dose inhaler in patients with asthma. Respir Med 1998; 92:325-330

(128) Ahrens RC, Hendeles L, Clarke WR, et al. Therapeutic equivalence of Spiros dry powder inhaler and Ventolin metered dose inhaler: a bioassay using methacholine. Am J Respir Crit Care Med 1999; 160:1238-1243

(129) Morice AH, Andrews B, Taylor M. Comparison of the effect on bronchial hyperresponsiveness of beclomethasone dipropionate administered via a novel multidose dry-powder inhaler or a conventional pressurised metered dose inhaler. Respiration 2000; 67:298-305

(130) Hansen NC. Terbutaline as powder inhalation from Bricanyl Turbuhaler compared to terbutaline as nebulizer solution in severe chronic airways obstruction. Eur Respir J 1989; 2:716-720

(131) Pauwels R, Lamont H, Hidinger K, et al. Influence of an extension tube on the bronchodilator efficacy of terbutaline delivered from a metered dose inhaler. Respiration 1984; 45:61-66

(132) Dorow P, Hidinger KG. Terbutaline aerosol from a metered dose inhaler via a 750 ml spacer: effect on large and small airways. Eur J Clin Pharmacol 1982; 22:511-514

(133) Gimeno F, van Veenen R, Berg WC, et al. A placebo-controlled comparison between the bronchodilatory effects of ipratropium bromide inhaled as a dry powder and by metered dose inhaler in chronic obstructive pulmonary disease. Ann Allergy 1988; 61:341-343

(134) Rammeloc RHU, Luursema PB, Sips AP, et al. Therapeutic equivalence of a fenoterol/lpratropium bromide combination (Berodual) inhaled as a dry powder and by metered dose inhaler in chronic obstructive airway disease. Respiration 1992; 59:322-326

(135) Formgren H, Sjokvist A, Stahl E, et al. Terbutaline in COPD comparison between Turbuhaler and chlorofluorocarbon (CFC) inhaler. Lung 1994; 172:271-280

(136) Balzano G, Battiloro R, Biraghi M, et al. Effectiveness and acceptability of a domiciliary multidrug inhalation treatment in elderly patients with chronic airflow obstruction: metered dose inhaler versus jet nebulizer. J Aerosol Med 2000; 13:25-33

(137) Beaty R, Harman E, Molino L, et al. The dose-response of albuterol MDI during acute attacks of nocturnal asthma [abstract]. Am Rev Respir Dis 1992; 145:A66

(138) Nelson HS, Busse WW, deBoisblanc BP, et al. Fluticasone propionate powder: oral corticosteroid-sparing effect and improved lung function and quality of life in patients with severe chronic asthma. J Allergy Clin Immunol 1999; 103: 267-275

(139) Ram FSF, Brocklebank D, Muers MF, et al. Pressurized metered-dose inhalers versus all other hand-held inhalers devices to deliver bronchodilators for chronic obstructive pulmonary disease. Cochrane Database Syst Rev (database online). Issue 1, 2002

(140) Lipworth B, Williams I, Senn S, et al. Electronic letters. BMJ 2001. Available at: http://bmj.bmjjournals.com/cqi/eletters/323/7318/896

(141) Agarwal S. Electronic letter. BMJ 2002. Available at: http:// bmj.bmjjournals.com/cqi/eletters/323/7318/901 Accessed April 4, 2002

(142) Dolovich MB, MacIntyre NR, Andersen PJ, et al. Consensus statement: aerosols and delivery devices; American Association for Respiratory Care. Respir Care 2000; 45:589-593

Myrna B. Dolovich, PEng; Richard C. Ahrens, MD; Dean R. Hess, PhD, RRT, FCCP; Paula Anderson, MD, FCCP; Rajiv Dhand, MD, FCCP; Joseph L. Rau, PhD, RRT; Gerald C. Smaldone, MD, PhD, FCCP; and Gordon Guyatt, MD, FCCP

American College of Chest Physicians/American College of Asthma, Allergy, and Immunology.

* From the Faculty of Health Sciences (Professor Dolovich) and the Department of Clinical Epidemiology and Biostatistics (Dr. Guyatt), McMaster University, Hamilton, ON, Canada; the Division of Pediatric Allergy and Pulmonary Diseases (Dr. Ahrens), Roy J. and Lucille A. Carver College of Medicine, University of Iowa, Iowa City IA; Harvard Medical School (Dr. Hess), Boston, MA; the Division of Pulmonary and Critical Care Medicine (Dr. Anderson), University of Arkansas for Medical Sciences, Little Rock, AK; the Division of Pulmonary, Critical Care, and Environmental Medicine (Dr. Dhand), University of Missouri-Columbia, Columbia, MO; Cardiopulmonary Care Sciences (Dr. Rau), Georgia State University, Atlanta, GA; and the Department of Medicine (Dr. Smaldone), Pulmonary/Critical Care Division, State University of New York at Stony Brook, Stony Brook, NY.

Professor Dolovich has served as a speaker for Forest Laboratories, 3M Pharma, and Aventis, and as a consultant for GlaxoSmithKline and Delex Therapeutics, and has received research funding from 3M Pharma Trudell Medical International, and Altana Pharma. Dr Ahrens in the past 19 months has received research funding from or has had a consulting relationship with the following organizations with a potential financial interest in the subject of the manuscript: AstraZeneca; Aventis; Boehringer Ingelheim; GlaxoSmithKline; Innovata Biomed Limited; Medic-Aid Limited; Monaghan Medical Corporation; and 3M Corporation. Dr. Hess has served as a consultant for Part and has received research funding from Cardinal Health. Dr. Anderson has participated in clinical trials for GlaxoSmithKline, Boehringer Ingelheim, Astra-Zeneca, and Novartis. Dr. Dhand has served as a speaker for GlaxoSmithKline and Boehringer Ingelheim, has sponsored meetings for GlaxoSmithKline, Boehringer Ingelheim, and Sepracor, and has performed research funded by Sepracor Inc and Omron. Dr. Rau has no financial interest or involvement in any organization with a direct financial interest in the subject of this article, but he has served as a consultant for Respironics, as a speaker for Sepracor Pharmaceutical, and as a consultant and speaker for and performed research funded by Trudell Medical International and Monaghan Medical Corporation. Dr. Smaldone has served as a consultant to several device and pharmaceutical companies that are connected to aerosol therapy, primarily the nebulization of drugs. Those companies with a direct financial interest in nebulization include Monaghan/Trudell Medical International, Aerogen, Part, and Profile Therapeutics.

Manuscript received February 25, 2004; revision accepted August 25, 2004.

Reproduction of this article is prohibited without written permission from the American College of Chest Physicians (e-mail: permissions@chestnet.org).

Correspondence to: Myrna B. Dolovich, PEng, Faculty of Health Sciences, McMaster University, 1200 Main St West, HSC 1V18, Hamilton, ON, Canada L8N 3Z5; e-mail: mdolovic@mcmaster.ca

COPYRIGHT 2005 American College of Chest Physicians
COPYRIGHT 2005 Gale Group

Return to Dornase alfa
Home Contact Resources Exchange Links ebay